![FEATURES](/images/new-backgrounds/39235/392353x1.webp)
FEATURES
High Efficiency Downflow 90+ Gas Furnace
Solid state integrated control monitors the burner flame and limit circuit continuously. Blower timing has adjustable OFF settings. Provides humidifier and electronic air cleaner connections.
Electrical 2 x 4 junction box can be moved outside of cabinet for disconnect.
Vent switch protects against blocked flue.
Counterflow heat exchanger orientation and aluminized steel tubular design, means improved efficiency and durability.
Aluminized steel
Factory installed drain for reliable performance.
STANDARD EQUIPMENT
Pressure switch assures proper operation of the induced draft system.
Induced draft blower provides quiet and reliable operation.
Supply air limit.
Remote flame sensor for proof of flame
Direct vent; draft inducer; pressure switch; redundant main gas control;
SPECIFICATIONS
FG6RL MODEL NUMBERS: |
|
|
|
|
|
|
|
|
|
|
|
40,000 | 60,000 | 80,000 | 100,000 | 120,000 | |
Heating Capacity - Btuh | 36,000 | 56,000 | 74,000 | 93,000 | 112,000 |
AFUE | 90+ | 92.1 | 92.1 | 92.1 | 92.1 |
Blower D x W | 10 x 6 | 10 x 6 | 10 x 10 | 10 x 10 | 11 x 10 |
Motor H.P. | 1/3 - 3 - PSC | 1/3 - 3 - PSC | 1/2 - 4 | 1/2 - 4 | 3/4 - 4 |
Motor FLA | 7.0 | 7.0 | 9.0 | 9.0 | 11.1 |
Maximum Ext. SP - In. W.C. | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 |
Temperature Rise Range - °F | 35 - 65 | 40 - 70 | 45 - 75 | 50 - 80 | 45 - 75 |
|
|
|
|
|
|
Note: All models are 115V, 60 Hz. Gas Connections are 1/2" N.P.T. AFUE = Annual Fuel Utilization Efficiency
(a) Ratings to 2,000 ft. Over 2,000 ft. reduce 4% for each 1,000 ft. above sea level.
2