SAFETY AND WARNINGS

IMPORTANT SAFETY INSTRUCTION

1)Read these instructions.

2)Keep these instructions.

3)Heed all warnings.

4)Follow all instructions.

5)Do not use this apparatus near water.

6)Clean only with dry cloth.

7)Do not block any ventilation openings, install in accordance with the instructions.

8)Do not install near any heat sources such as radiations, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.

9)Do not defeat the safety purpose of the polarized plug. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.

10)Protected the power cord from being walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.

11)Only use attachments/accessories specified by the manufacturer.

12)Unplug this apparatus during lighting storms or when unused for long periods of time.

13)Refer all servicing to qualified service personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.

14)Mains plug is used as the disconnect device, the disconnect device shall remain readily operable.

15)The ventilation should not be impeded by covering the ventilation openings with items, such as newspapers, table-cloth, curtains, etc.

16)No naked flame sources, such as lighted candles, should be placed on the apparatus.

17)Attention should be drawn to the environmental aspects of battery disposal.

18)The use of apparatus in moderate climate.

19)The apparatus shall not be exposed to dripping or splashing and that no objects filled with liquids, such as vases, shall be placed on the apparatus.

CAUTION

RISK OF ELECTRIC SHOCK

DO NOT OPEN!

CAUTION

TO REDUCE THE RISK OF ELECTRIC SHOCK, DO NOT REMOVE COVER (OR BACK).NO USER SERVICEABLE PARTS INSIDE. REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.

The symbol indicates that dangerous voltages constituting a risk of electric shock are present within this unit.

The symbol indicates that there are important operating and maintenance instructions in the literaturaccompanying this unit.

WARNING:

To reduce the risk of fire or electric shock, do not expose this apparatus to rain or moisture.

WARNING:

The batteries shall not be exposed to excessive heat such as sunshine, fire or the like.

This symbol indicates that this product incorporates double insulation between hazardous mains voltage and user accessible parts. When servicing use only identical replacement parts.

This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.

This Westinghouse product has earned the ENERGY STAR® for meeting U.S. Federal energy efficiency guidelines as set by the Department of Energy and Environmental Protection agency. The ENERGY STAR® program exists to provide energy saving guidelines and help promote energy efficient products and practices. Changes to certain features, settings and functions of this TV can change and/or increase its power consumption. Depending on how settings are changed, power consumption may exceed the limits required for ENERGY STAR® qualification.

-2-

Page 3
Image 3
Westinghouse vr-2418 manual Important Safety Instruction, Safety and Warnings

vr-2418 specifications

The Westinghouse VR-2418 is a sophisticated and versatile vacuum circuit breaker designed for medium voltage applications. This equipment is engineered to provide reliable protection for electrical systems, ensuring operational safety and efficiency.

One of the standout features of the VR-2418 is its compact design, which allows for easy installation in various environments, including substations and industrial facilities. With a rating of up to 24 kV, the VR-2418 is capable of handling significant electrical loads while maintaining a small footprint.

The VR-2418 utilizes advanced vacuum interruption technology, which is essential for achieving fast and efficient current interruption. In this system, the contacts are housed in a vacuum chamber, minimizing the effect of arcing and ensuring a longer service life. This technology not only enhances performance but also contributes to improved maintenance intervals, making it a cost-effective solution for end-users.

In terms of operational characteristics, the VR-2418 is equipped with automatic and manual tripping mechanisms, allowing for flexibility in various applications. This dual approach ensures that the circuit breaker can respond promptly to overloads or faults while also providing users with manual control when required. Additionally, the device features a robust spring-operated mechanism that guarantees high-speed operation, crucial for minimizing downtime in critical systems.

The VR-2418's integrated control systems further augment its capabilities. It can be equipped with advanced monitoring and diagnostic tools, allowing operators to oversee the performance of the circuit breaker remotely. This feature not only enhances operational efficiency but also aids in predictive maintenance practices, reducing the risk of unplanned outages.

Moreover, the Westinghouse VR-2418 complies with international standards for safety and environmental responsibility, making it a suitable choice for modern electrical infrastructure. The vacuum circuit breaker is designed with materials that promote sustainability while maintaining high performance and reliability.

In summary, the Westinghouse VR-2418 is a state-of-the-art vacuum circuit breaker that combines advanced technology, compact design, and enhanced operational features. Its reliability, flexibility, and efficiency make it an excellent choice for a wide variety of medium voltage applications. Whether in industrial settings or electrical distribution networks, the VR-2418 proves to be a critical component in ensuring system integrity and safety.