FIGURE 2.

GROUP A:

CONNECT TO BLACK

CONNECT TO WHITE

HOUSE WIRE

GROUP B: HOUSE WIRE

BLACK

 

WHITE

WHITE OR GREY WITH TRACER

WHITE OR GREY WITHOUT TRACER

BROWN, GOLD OR BLACK

BROWN, GOLD OR BLACK WITH TRACER

WITHOUT TRACER

 

NOTE: When parallel wire (SPT I & SPT II) is used; the neutral wire is square shaped and ridged, and the hot wire will be round in shape and smooth. (See below.)

FIGURE 2.

À BRANCHER AU FIL NOIR

À BRANCHER AU FIL BLANC

GROUPE A: DE LA RÉSIDENCE

GROUPE B: DE LA RÉSIDENCE

NOIR

BLANC

BLANC OU GRIS AVEC TRACEUR

BLANC OU GRIS SANS TRACEUR

BRUN, DORÉ OU NOIR SANS TRACEUR

BRUN, DORÉ OU NOIR AVEC TRACEUR

NOTA: Dans le cas des fils parallèles (SPT I et SPT II), le fil neutre est carrè et Côtelè et le fil chargè est rond et lisse. (Voir ci-dessus)

FIGURA 2.

GRUPO A:

CONÉCTELO AL CABLE

CONÉCTELO AL CABLE

NEGRO DE LA CASA

GRUPO B: BLANCO DE LA CASA

NEGRO

 

BLANCO

BLANCO O GRIS CON MARCAS

BLANCO O GRIS SIN MARCAS

MARRÓN, DORADO O NEGRO SIN MARCAS

MARRÓN, DORADO O NEGRO CON MARCAS

NOTA: Cuando se usa cable en paralelo (SPT 1 y SPT 2), el cable neutro es cuadrado y acanalado, y el cable vivo es redondo y liso. (Ver abajo.)

WARNING

Turn off electricity to the mounting site before beginning installation.

Mounting instructions must be followed exactly as shown for the fixture to be safely supported.

MISE EN GARDE

Coupez le courant au site de montage avant de commencer l’installation.

Assurez-vous de suivre les instructions de montage exactement comme illustré afin que l’appareil d’éclairage soit installé de façon sécuritaire.

ADVERTENCIA:

Desconecte el suministro eléctrico al sitio de mon- taje antes de comenzar la instalación.

Se deben seguir las instrucciones de montaje exactamente como se indican para que el aparato tenga un soporte seguro.

11

Page 11
Image 11
Westinghouse W-019 owner manual Mise EN Garde, Advertencia

W-019 specifications

The Westinghouse W-019 is a significant advancement in the field of nuclear power generation, developed to fulfill the growing demand for clean, efficient, and sustainable energy. This reactor model stands as an exemplar of modern nuclear technology, characterized by its innovative safety features, operational efficiency, and environmental considerations.

At its core, the Westinghouse W-019 employs advanced Generation III+ reactor technology, which incorporates numerous enhancements over preceding models. One of its standout features is the incorporation of passive safety systems. These systems utilize natural forces such as gravity, natural circulation, and convection to maintain safe cooling, even in the event of a loss-of-coolant accident. This design significantly reduces reliance on active mechanical systems, enhancing the overall safety of the reactor.

The W-019 also boasts a compact and modular design, which allows for easier transportation, construction, and scaling. This modularity enables plants to be built incrementally, accommodating regional energy demands while minimizing upfront capital expenditure. The reactor's modular approach also facilitates quicker deployment, providing communities with a rapid solution to meet their energy needs.

In terms of operational efficiency, the Westinghouse W-019 is designed for a longer fuel cycle, reducing the frequency of refueling outages. This not only increases the plant's overall capacity factor but also lowers operational costs. The reactor utilizes advanced fuel technology, including improved fuel compositions that enhance performance and longevity while minimizing waste production.

The W-019 is also notable for its environmental safeguards. The reactor's design contributes to a significant reduction in carbon emissions, making it an attractive option for nations looking to transition to low-carbon energy sources. By harnessing nuclear power, countries can reduce their dependence on fossil fuels, fostering a cleaner, more sustainable energy future.

In summary, the Westinghouse W-019 represents a forward-thinking approach to nuclear energy. Its innovative safety features, modular construction, extended fuel cycle, and commitment to environmental responsibility position it as a pivotal player in the global energy landscape. As the world continues to seek sustainable energy solutions, the W-019 stands out as a beacon of advanced engineering, promising a reliable and clean energy source for the future.