Westinghouse w-031 owner manual Mounting and Wiring Instructions, Fixture Assembly Instructions

Models: w-031

1 12
Download 12 pages 42.97 Kb
Page 4
Image 4

MOUNTING AND WIRING INSTRUCTIONS

CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Remove cap nuts (A) from back plate (B) and remove universal mounting plate or cross bar (C) (see fig. 1).

3.Secure universal mounting plate or cross bar (C) to outlet box (D) with outlet box screws (E) (not included).

NOTE: For fixtures with an unassembled tail, follow steps 4 and 5. For fixtures with an assem- bled tail (or no tail) proceed to step 6.

4.Screw center pipe (F) into bottom of fixture cage (H).

5.Slide tail (I), top break (J) and bottom break (K) over center pipe (F). Secure with finial (L).

NOTE: If no tail is desired, remove round nut (G) from bottom of fixture cage (H) and replace with finial (L).

6. Identify color coding of fixture wires (see figure 2 on page 11).

NOTE: For fixtures employing a grounded convenience outlet: This fixture employs a grounded type receptacle and is not intended for connection to a two-wire ungrounded source of supply.

7.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

8.Fit wire connector (M from fig. 1) over wires and twist until there is a firm connection. If wire connector (M) easily comes off, reattach wire connector (M) and check again for a firm connection (see figure 1).

9.Repeat steps 7 and 8 with the white (group B from fig. 2) fixture wire and outlet box wires.

10.Partially thread green grounding screw (N) into side hole (O) on universal mounting plate or cross bar (C) (see fig.1).

11.Wrap ground wire from fixture and ground wire (metal or green wire) from outlet box (D) around green grounding screw (N) on universal mounting plate or cross bar (C).

12.Tighten green grounding screw (N). Do not over tighten.

13.Tuckwires inside outlet box (D).

FIXTURE ASSEMBLY INSTRUCTIONS

1.Place back plate (B) over mounting screws (P) (see fig. 1).

2.Secure into place with cap nuts (A).

3.Remove two inner cap nuts (Q) from top of fixture cage (H).

4.Install lamp(s). Do not exceed recommended wattage.

5.Place fixture cover (R) over fixture cage (H) and secure with inner cap nuts (Q).

6.Turn power back on at circuit box.

4

Page 4
Image 4
Westinghouse w-031 owner manual Mounting and Wiring Instructions, Fixture Assembly Instructions

w-031 specifications

The Westinghouse W-031 is a cutting-edge generator designed for versatile applications, offering reliable power solutions for both residential and commercial needs. Leveraging advanced technology, the W-031 exemplifies the brand's commitment to efficiency, longevity, and user-friendly design. This generator is powered by a robust engine, capable of delivering a substantial amount of wattage, making it suitable for backing up essential appliances, construction sites, and recreational activities.

One of the standout features of the Westinghouse W-031 is its dual-fuel capability, allowing it to run on both gasoline and propane. This flexibility not only provides users with options depending on availability but also enhances overall fuel efficiency. Users can switch between fuels easily, ensuring optimal performance regardless of the situation. The generator is equipped with a large fuel capacity, which extends its operational time, reducing the need for frequent refueling during extended outages or work periods.

In terms of technology, the W-031 comes with a user-friendly control panel that includes various outlets, such as 120V sockets, ensuring compatibility with a wide range of devices. The generator also features an automatic voltage regulator that stabilizes voltage output, protecting sensitive electronics from damage. Safety features are paramount, including low oil shutdown and overload protection, which enhance the reliability and durability of the unit.

Another characteristic that sets the W-031 apart is its noise reduction technology, allowing it to operate quietly compared to many traditional generators. This feature is particularly beneficial in residential areas or while camping, where excessive noise can be a nuisance. Compact design and built-in wheels provide ease of transport, making it practical for users on the go.

The Westinghouse W-031 is also renowned for its impressive runtime, as it can operate for several hours on a single tank of fuel, depending on the load. Its maintenance-friendly design simplifies upkeep, ensuring optimal performance with minimal effort. With a combination of power, versatility, and advanced safety features, the Westinghouse W-031 stands out as an ideal choice for anyone seeking a reliable generator solution. Whether powering home appliances during an outage or providing energy on a job site, it delivers exceptional performance that can be trusted in critical situations.