CAUTION: For fixtures labeled for outdoor and wet location use, provide a water-tight seal between the fixture and the mounting surface by using silicone or similar caulking.

NOTE: Underwriters Laboratories (UL) does not require all fixtures to have ground wires. These fixtures meet all UL specifications.

1.Turn off power at circuit box to avoid possible electric shock.

2.Thread mounting screws (A) into mounting bar (B) approximately 1/4 inch (see fig. 1).

3.Secure mounting bar (B) to outlet box (C) with outlet box screws (D) (not included).

4.Thread nipple (F) into canopy loop (H), place canopy (L) over nipple (F), then secure nipple

(F) with lockwasher (G) and hex nut (E). May be preassembled (do not twist or kinkwires).

5.Thread fixture loop (K) onto top assembly (Q) (see fig. 1).

6.Open one link on bottom end of chain (J). Attach to fixture loop (K). Securely close link on chain (J).

7.Lace wires up through every other link on chain (J) then through canopy loop (H), canopy (L) and nipple (F).

8.Open one link on top end of chain (J). Attach to canopy loop (H) and canopy (L). Securely close link on chain (J).

9.Identify color coding of fixture wires (see fig. 2 on page 18).

10.To connect wires, take black fixture wire (group A from fig. 2) and place evenly against black outlet box wire. Do not twist wires.

11.Fit wire connector (M from fig. 1) over wires and twist until there is a firm connection. If wire connector (M) easily comes off, reattach and check again for a firm connection.

12.Repeat steps 10 and 11with the white (group B from fig. 2) fixture wires and outlet box wires.

13.Partially thread green grounding screw (N) into side hole (O) on mounting bar (B) (see fig.1.)

14.Wrap ground wire from fixture around green grounding screw (N), leaving enough excess wire to then connect ground wire and outlet box wire with wire connector.

15.Tighten green grounding screw (N). Do not over tighten.

16.Tuckwires inside outlet box (C).

PENDANT FIXTURE ASSEMBLY INSTRUCTIONS

1.Secure fixture loop (H) to nipple (F) by raising canopy (L) to ceiling. Allow mounting screws (A) to protrude through openings in canopy (L), and secure with cap nuts (P).

2.Install lamp (s). Do not exceed recommended wattage.

3.Turn power back on at circuit box.