‘SCl&VS

20 n Attach front bv first removing the two, #8 x 9?i mm (318”) screws from base; then insert front tabs into top of cabinet and swing front in place. Attach bottom of front by reinserting the two screws.

4 n Insert the frame in the wall opening. Square the level frame. Nail frame securely to the wall studs.

Floor Damage

Remove air conditioner from carton and place on cardboard.

Failure to do so may cause damage to floor covering.

16 H Secure vertical and angle supports together. Attach supporti? to bottom of cabinet. But Do Not tiahten bolts at this time. Attach wall rail to angle supports. Slide each support assembly toward house until wall rail is positioned firmly against wall.

Note: If your house is constructed of material that could be damaged by wall-mounting support, fasten a board between wall rail and house.

17 I Tighten bolts securely with a

11.1mm (7/16”) socket and socket wrench. Tighten angled support bolts last so wall rail fits tightly against house,

THROUGH-THE-WALL

INSTALLATION

INSTRUCTIONS... FOR SLIDE-OUT CHASSISMODEL ONLY.

It is the customer’s responsibility and obligation to have this product installed by a qualified technician familiar with through-the-wall room air conditioner installations.

apptoptlafe header If required

frhl+,casing

w Loosen, but Do Not remove grounding wire screw. Disconnect grounding wire.

Personal Injury/Product

Damage Hazard

Install window-lock bracket to prevent air conditioner from falling out of window.

\ ‘,\\I II louvers. I I

thlcknes

Failure to do so could result in personal injury or product damage.

drain

CUD

provided, place through hole in cabinet rail as

18 n Insert window rail seal behind the top of the lower window sash and against the glass of the upper window. Place window-lock bracket on top of lower window and against upper window sash. Use a 2.4 mm (3/32”) drill bit to drill a starter hole through the hole in the bracket. Attach window-lock bracket with wood screw. Seal small openings around window with gum- type sealer.

Frame construction

approptlafe header If required

I 254 mm (10’3

alternate consftucffon for plasfet

Provide 30 mm (l-3/169

&fe&an&efor \ I I I\\\\ power supply car

entry on leff dde

30 mm (l-3/16”) clearance for

Brick veneer construction

1 n When using a wood, metal or plastic molding, the finish frame should line up with inside wall. If the plastered wall isto be flush with the cabinet and no molding is used, the finish frame must be set 12.7 mm (l/2”) into the wall.

6 w Pull on handles; slide air conditioner out of cabinet and place on cardboard.

7 n Insert cabinet into wall opening. The top of the cabinet should extend

12.7mm (l/2”) into room. If there istrim, the cabinet should extend 12.7 mm (l/2”) in front of trim.

Property Damage

Check that air conditioner cabinet is tilted to the outside so that water will run to the outside.

Failure to do so may cause damage to floor covering or wall.

8 n Place level inside cabinet on the right side. There should be a tilt to the outside of approximately one bubble. Place the level on the left side and check.

9 n Use the insulation removed in Step 2 to seal opening between cabinet and frame.

Electrical Shock Hazard

Grounding wire from the air conditioner must be connected to the cabinet.

Failure to do so could result in electrical shock.

19 n Inset-t air conditioner into cabinet. Reattach grounding wire to grounding screw. Put excess grounding wire between coil and grey beaded foam.

use 66 cm-

 

 

dimension

 

 

50.2 cm (19-3/4”)

 

(includes

allowance

ul

for 12.7 mm (l/2”)

 

flange on

b&&m’ of

 

cabinet).

 

 

2 w Cut opening through the wall. Remove insulation.

7

6

Dimension depends on

wall thickness and type of molding.

10 n Drill four holes on each side and two through the top of the cabinet into the frame. Use ten #lO x 25.4 mm (1”) wood screws (not provided) to attach cabinet to frame. Do Not overtighten screws or cabinet will distort and provide a poor air seal between

3 n Use 25.4 mm (1”) or heavier lumber for wood frame. Measure depth of wall opening and frame.

Apply wood preservative to the outside exposed surface.

Panel C

Page 4
Image 4
Whirlpool 1166073 installation instructions THROUGH-THE-WALL Installation, Panel C