20 n Attach front bv first removing the two, #8 x 9?i mm (318”) screws from base; then insert front tabs into top of cabinet and swing front in place. Attach bottom of front by reinserting the two screws.
4 n Insert the frame in the wall opening. Square the level frame. Nail frame securely to the wall studs.
Floor Damage
Remove air conditioner from carton and place on cardboard.
Failure to do so may cause damage to floor covering.
16 H Secure vertical and angle supports together. Attach supporti? to bottom of cabinet. But Do Not tiahten bolts at this time. Attach wall rail to angle supports. Slide each support assembly toward house until wall rail is positioned firmly against wall.
Note: If your house is constructed of material that could be damaged by
17 I Tighten bolts securely with a
11.1mm (7/16”) socket and socket wrench. Tighten angled support bolts last so wall rail fits tightly against house,
THROUGH-THE-WALL
INSTALLATION
INSTRUCTIONS... FOR
It is the customer’s responsibility and obligation to have this product installed by a qualified technician familiar with
apptoptlafe header If required
frhl+,casing
w Loosen, but Do Not remove grounding wire screw. Disconnect grounding wire.
Personal Injury/Product
Damage Hazard
Install
\ ‘,\\I II louvers. I I
thlcknes
Failure to do so could result in personal injury or product damage.
drain
CUD
provided, place through hole in cabinet rail as
18 n Insert window rail seal behind the top of the lower window sash and against the glass of the upper window. Place
Frame construction
approptlafe header If required
I 254 mm (10’3
alternate consftucffon for plasfet
Provide 30 mm
&fe&an&efor \ I I I\\\\ power supply car
entry on leff dde
30 mm
Brick veneer construction
1 n When using a wood, metal or plastic molding, the finish frame should line up with inside wall. If the plastered wall isto be flush with the cabinet and no molding is used, the finish frame must be set 12.7 mm (l/2”) into the wall.
6 w Pull on handles; slide air conditioner out of cabinet and place on cardboard.
7 n Insert cabinet into wall opening. The top of the cabinet should extend
12.7mm (l/2”) into room. If there istrim, the cabinet should extend 12.7 mm (l/2”) in front of trim.
Property Damage
Check that air conditioner cabinet is tilted to the outside so that water will run to the outside.
Failure to do so may cause damage to floor covering or wall.
8 n Place level inside cabinet on the right side. There should be a tilt to the outside of approximately one bubble. Place the level on the left side and check.
9 n Use the insulation removed in Step 2 to seal opening between cabinet and frame.
Electrical Shock Hazard
Grounding wire from the air conditioner must be connected to the cabinet.
Failure to do so could result in electrical shock.
19 n
use 66 cm- |
|
| |
dimension |
|
| |
50.2 cm |
| ||
(includes | allowance | ul | |
for 12.7 mm (l/2”) | |||
| |||
flange on | b&&m’ of |
| |
cabinet). |
|
|
2 w Cut opening through the wall. Remove insulation.
7
6
Dimension depends on
wall thickness and type of molding.
10 n Drill four holes on each side and two through the top of the cabinet into the frame. Use ten #lO x 25.4 mm (1”) wood screws (not provided) to attach cabinet to frame. Do Not overtighten screws or cabinet will distort and provide a poor air seal between
3 n Use 25.4 mm (1”) or heavier lumber for wood frame. Measure depth of wall opening and frame.
Apply wood preservative to the outside exposed surface.