Whirlpool 1982 manual Carpentry, Electricalrequirements, Do Not Install This Oven In A Base

Models: 1982

1 4
Download 4 pages 42.21 Kb
Page 2
Image 2
DO NOT INSTALL THIS OVEN IN A BASE

-

48 INCH

 

 

 

FLEX. CABLE

 

, IF

28-5/8”

*F:OR A 36” OPEN OVEN DOOR HEIGHT

28%” MINIMUM

FIGURE l--ROUGH-IN DIMENSIONS

IS AVAILABLE

THE

CUTOUT

SHOULD BE MADE

28-5/8”.

DO NOT INSTALL THIS OVEN IN A BASE

CABINET WITH A COUNTERTOP ABOVE IT.

1. CARPENTRY

Refer to Figure 1 for the dimensions of the oven and the space necessary to receive the oven. The oven support surface may be solid plywood or similar material but the contact surface must be level from side to side and from front to rear. This surface is 2%” below the open door height.

NOTE 1: The oven support surface must be flush with the bottom of the cabinet cut out.

WARNING: TO AVOID DAMAGE TO CABINET AND/OR POOR BAKE PERFORMANCE, DO NOT BLOCK OVEN VENT.

2. ELECTRICALREQUIREMENTS

IMPORTANT: OBSERVE AU GOVERNING CODES

AND ORDINANCES

SAVE THESE INSTRUCTIONS FOR THE LOCAL

ELECTRICAL INSPECTOR’S USE

A.A three-wire or four-wire single phase 120/240 volt 60Hz AC only electrical supply (or three-wire or four-wire 120/206 volt if specified on nameplate) is required on a separate circuit fused on both sides of the line (time-delay fuse or circuit breaker is recommended). Do NOT fuse neutral. The fuse size must not exceed the circuit rating of the appliance specified on the nameplate.

NOTE: Wire sizes and connections must conform with the fuse size and rate of the appliance in accordance with the National Electrical Code and local codes and ordinances.

Do not use an extension cord.

6.The appliance should be connected to the fused discon- nect (or circuit breaker) box through flexible armored or non-metallic sheathed cable. The flexible armored cable extending from the appliance should be connected directly to the junction box. The junction box should be located as shown in Figure 1 so that as much slack as possible remains in the cable between the box and the appliance so that it can be moved if servicing is ever necessary.

C. A suitable strain relief must be provided to attach the flexible armored cable to the junction box.

D. Electrical Connection.

It is the personal responsibility and obligation of the customer to contact a qualified installer to assure that the electrical installation is adequate and is in conformance with the National Electrical Code and local code ordinances.

Electrical ground is required on this appliance.

This appliance is equipped with copper lead wires. If the connection is made to aluminum house wiring, use only special connectors which are approved for joining copper and aluminum wires, in accordance with the National Electrical Code and local codes and ordinances.

This appliance is manufactured with a white neutral power supply wire and a frame-connected green ground wire.

2

Page 2
Image 2
Whirlpool 1982 Carpentry, Electricalrequirements, Do Not Install This Oven In A Base, Cabinet With A Countertop Above It