Proper rnsiallation ISyour responsibility Make we you hove everyihing necessary for correct Instollol~on It 1sthe personal responsibility end obllgatlon of the customer to contact o quaIlfled Installer to assure that electrlcol ond plumbing ~nstollal~on mecl nal~onai and local codes and ordlnonces

IMPORTANT: Observe all governing codes and ordinances.

DO NOT install dishwasher over carpeted floor

ElectrIcal ground

-is reauired See Elecirrcal requirements

Proper eleclrlcol. dram and water SUPPIV lines must be available or must be lnslallcd as speclfled wllhin shaded Oreo See Electrrcal. Water and Droln requrrements. Plumbing and wiring should not cross In front of motor or drshwoshcr legs

If plumbing ond electrrcal connecllsns ore not installed. complete the Electrical. Waler and Drain Connectrons Installation InstructIons frrst.

Check locatron where dlshwasher WIII be installed. The location should provide:

lEasy access to water. electricity

and drarnoge lines

. Convenient loadrng - the best pos11ron ISleft or rrght of kitchen sink.

. Openrng that is square for proper dishwasher operahon and appearance.

lCabinet front that ISoeroendiculor

to floor

lProtection so that water inlet valve and drain cannot freeze.

. l/4” minimum clearance between motor ond flooring to prevent motor overheating.

Electrical Shack Hazard~~-1l Electrical wiring and

components must not contact any plumbing material or drain hose.

l Cabinet opening must completely enclose sides, top and bock of dishwasher.

Failure to do so may result in personal injury from exposed wiring.

Personal Injury

Avoid opening dishwasher door before dishwcsher is installed. Dishwasher. betore il is inslolled may tip over when door is o&n&d resulting in personal injury or product damage.

,

Parts supplied for installation:

Remove parts from bag. Check that all parts were supplied.

Tools needed for fnstallation:

Panel A

Electrical requirements

Electrical Shock Hazard *Electrical ground is required on this OrJoliance. Check with (I

qualiiied electrician S you are in doubt as to whether the appliance Is property grounded.

Improper connection of the

equipment-grounding conductor con result in dectrical shock.

*Disconnect power to the junction box.

Failure to do 50 could result in serious injury or deoih.

*This appliance must be connected to a grounded, metallic permanent wirina

system. or a grounding - connector should be connected to the grounding terminal or wire lead on the appliance.

Failure to do so could result in serious injury or death.

l Do Not have a fuse in the neutral or grounding circuit.

lhhcckquld result in electrical

*DO Not use an extension cord with this appliance.

Such use may resull in a fire, electrical shock or otner personal injury.

A I P~volt. 60 Hz. AC only. 15 or 20 ampere, fused electrical supply Is required. Time-delay fuse or clrcutt

breaker is recommended. lt ls recommended that a separate circuit serving only this appliance be provided.

It ls the personal responsibilii and obligation of the customer to con&t a qualmd electdclan ta assure that the elect&al installation Is adequate ond Is in conformance with the National Electdcal Code, ANSVNFPA 7@!~test editlon. and local codes and ordinances.

The dishwasher can be connected with flexible armored or non-metallic sheathed copper cable (with groundlng wire).

A U.L.-listed strain relief or conduit connector must be installed ot each end of the Dower SUDDIVcable tat the dishwajher and bi {he junction box). Wire sizes (COPPER WIRE ONLV) must conform with the rating of the dishwasher.

Local codes may permtt the use of a U.L.-listed. flexible three-conductor l&gauge cord terminated with a three prong. grounding type plug. The cord must meet the National ElectrIcal Code. ANSl/NFPA 7C-lotest edttton and local codes and ordlnonces. The length of the cord must not exceed six feet. It must be routed so it does not touch the dishwosher motor or the lower portion of the dishwasher tub. A grommet (Part No. 302797) must cover the hole cut In a metol cabinet for the flexible cord. The flexible cord must be plugged into a mating three-prong grounding type wall receptcle. Follow Instructions packaged with the flexible cord.