Dryer location

and dimensions

WARNING

Explosion Hazard

Keep flammable materials and vapors, such as gasoline, away from dryer.

Place dryer at least 18 inches above the floor for a garage installation.

Failure to do so can result in death, explosion, or fire.

Dimensions shown with feet extended 1” from bottom of dryer.

11"

terminal block cover

 

power supply cord/cable strain relief

14"

43-1/8"

38-1/4"

29-1/4"* (models with flush

mounted door handle)

30-1/4"* (models with

extended door handle)

27”

The dryer door extends 14" from the front of the dryer when fully opened.

Exhaust dimensions

back exhaust

4"

14-1/8"

left or right side exhaust

4-1/4"

10-1/4"

bottom exhaust

*Most models will require at least 5" clearance behind the dryer for the dryer vent.

For proper drying performance:

 

The location must provide:

✔Level floor: Maximum slope under entire dryer

✔Protection from weather and water: Do not

should not be more than 1 inch. (If slope is greater

store or use dryer where it will be exposed to

than 1 inch, install Extended Dryer Feet Kit, Part

water and weather.

No. 279810.) Clothes may not tumble properly and

✔Room temperature above 45°F: If room

automatic sensor cycles may not operate correctly if

dryer is not level.

temperature is below 45°F, automatic cycles may

✔Sturdy floor to support dryer weight of

not shut off.

120 pounds.

7-1/4"

14-1/8"

It is your responsibility to:

✔Observe all governing codes and ordinances.

✔Check code requirements: Some codes limit or do not permit installation of clothes dryers in garages, closets, mobile homes or sleeping quarters. Contact your local building inspector.

✔Comply with the installation specifications and dimensions.

✔Consider spacing requirements for companion appliances.

✔Make sure you have everything necessary for proper installation.

✔Properly install dryer.

✔Contact a qualified installer to insure that the electrical installation meets all national and local codes and ordinances.

Recessed area/closet installation

WARNING — To reduce the risk of fire this appliance

MUST BE EXHAUSTED OUTDOORS

Recessed area installation

Closet/confined area installation

Installation clearances

Use recommended clearance for easier installation.

Recommended/Minimum

front view

If a closet door is installed: The minimum unobstructed air openings are required. Louvered doors with equivalent air openings are acceptable.

 

Back

Sides

Top

Front

Recessed

5"/0"

1"/0"

18"/15"

—

Closet

5"/0"

1"/0"

18"/15"

1"/1"

• A clothes dryer produces combustible lint and

must be exhausted outdoors.

• If codes permit, dryer may be installed in a

recessed area or closet using dimensions shown.

• Dimensions are in inches and are the minimum

allowable.

• Additional spacing should be considered for ease

of installation and servicing. Companion

appliance spacing should also be considered.

15"

0"*0"*

* Wall, door and floor molding may require

additional spacing.

front view

 

3"

 

closet

48

door

sq. in.**

 

24 sq. in.**

 

 

3"

 

1"

side view

14"

max.

0"***

**Minimum top and bottom air openings for closet door.

***External exhaust elbow requires additional space.

Electrical

requirements

If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.

Important: Observe all governing codes and ordinances.

A four-wire or three-wire, single phase, 120/240- volt, 60-Hz, AC-only, electrical supply (or four-wire or three-wire, 120/208-volt if specified on model/serial rating plate) is required on a separate 30-ampere circuit, fused on both sides of the line. A time-delay fuse or circuit breaker is recommended.

Recommended ground method

It is the personal responsibility and obligation of the customer to contact a qualified electrician to assure that the electrical installation is adequate and is in conformance with the National Electrical Code, ANSI/NFPA 70 — latest edition**** and all local codes and ordinances.