7 .Electrical | Data |
|
|
Base | level |
|
|
Voltage | 220/230/50 | VIV/Hz | |
Total | power | app. 3 | kW |
Fuses |
| 10/16 | A |
Water | connection up to | 25 | °C |
Timer
Model | EC 4326 |
Basic step times | 15",45",60" 120", 270" |
Heating
1 | Element | system: | 220 | V | 2800/1800 W | app. 16,0 | Ohm | |||
|
|
|
| 230 | V | 3060 | W | app. 17,0 | Ohm | |
2 | Element | system: (CH + DK) |
|
|
|
|
|
|
| |
Element | A | 220 | V | 1850 | W | app. | 25,3 | Ohm | ||
Element | B | 220 | V | 950 W | app. | 49,5 | Ohm |
Motor
SP | 220 V/130 W | HI=121 Ohm | HA=30 Ohm | |
Capacitor | 3 IJF |
|
|
|
DP Motor | 220/240 | V | 30 W | 170 Ohm |
Timer motor | 220/240 | V |
| 5640 + 400 Ohm |
Valve |
|
|
|
|
Inlet valve |
|
|
|
|
Double valve | 220/240 | V | 6 W | 3620 Ohm |
Regeneration valve | 220/240 | V | 8 W | 2300 Ohm |
Relay |
|
|
|
|
Relay | 220/240 | V | 50/60 Hz | 5500 Ohm |
Thermostats | Indication | colour |
|
|
Thermostat | without |
| 40 °C | SP 40 :t 3 °C RSP 29 :t 5 °C |
Thermostat | red |
| 55 °C | SP 55 :t 3 °C RSP 40 :t 5 °C |
Thermostat | white |
| 65 °C | SP 68 :t 3 °C RSP 57 :t 5 °C |
Housing colour | brown |
|
|
|
Reset |
|
|
|
|
Safety thermostat | with manual reset |
| SP 180 :t 7 °C |
8.Water Levels
Basic | level | SP | 137 | :t 5 | RSP 40 | :t 5 | mm ws | |
Working level | SP | 137 | :t 5 | RSP | 40 | :t 5 | mm ws | |
Safety | level | SP | 150 | :t 5 | RSP | 100 :t 5 mm ws |
9.Water Measuring
Basic | level | 125 | mm |
Working level | 125 | mm | |
Safety | level | 136 | mm |
10.Regenerating Steps and Volumes
Figure | Volume | Steps | Water hardness |
Figure | 360 cm3 | 24 | < 30° dh = < 5,0 mmol/ I |