COperating position
front leveling leg
rear leveling leg
5.Remove cardboard shipping base from under range. Open broiler drawer. Use a 3/8" drive ratchet to lower rear leveling legs one- half turn. Use channel lock pliers to lower front leveling legs
Before moving range across floor, check that range is still on cardboard shipping base to protect floor covering.
6.Making sure the
• Look for the |
| |
bracket |
| |
securely attached to | range foot | |
floor. |
|
|
•Slide range back so rear range foot is under
7.If installing the range in a mobile
home, you MUST secure the range to the floor. Any method of securing the range is adequate as long as it conforms to “Manufactured Home Construction and Safety Standard,” Page 2.
8.Place rack in oven. Place level on rack, first side to side; then front to back.
If range is not level, pull range forward until rear leveling leg is free of the
Note: Oven must be level for satisfactory baking conditions.
DGas and electrical connections
All connections must be wrench-tightened.
Typical rigid pipe connection
pressure |
| |
regulator | 90˚elbow | |
| ||
90˚elbow | black iron | |
nipple union | ||
pipe | ||
| ||
union | manual | |
| gas | |
nipple | shutoff | |
valve | ||
| ||
1/2" to 3/4" | ||
gas pipe |
|
10.Use 15/16" combination wrench and channel lock pliers to attach the flexible connector to the adapters. Check that connector is not kinked.
12.Use a brush and liquid detergent to test all gas connections. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and tighten connections. Then check connections again. Clean all detergent from range. Replace broiler drawer.
13.Center the burner cap on burner base. Burner cap should be level when properly positioned. Place burner grates over burner.
14.Plug power supply cord into grounded electrical outlet.
Typical flexible connection
pressure regulator
use
90˚elbow |
| flexible |
| adapter | connector |
|
|
use
adapter
manual gas shutoff
1/2" to 3/4" valve gas pipe
A 1/2" male pipe thread is needed for connection to pressure regulator female pipe threads.
regulator shutoff valve in
“on” position
manual shutoff valve
“open” position
to range
gas supply
11.Check that range regulator shutoff
valve is in the “on” position. Open the manual shutoff valve in the gas supply line.
9.Apply
Page 5