Product Dimensions

Dimensions shown with feet extended 2.5 cm (1") from bottom of dryer.

27.9 cm

 

(11")

terminal block cover

Electrical Requirements

Important: Observe all governing codes and ordinances.

This dryer is supplied/fitted with an electricity supply cord and European 16A plug. It should be connected to electricity supply socket at the voltage shown on the rating plate. The minimum

109.5cm (43-1/8")

97.2cm (38-1/4")

74.3 cm

(29-1/4")

35.9 cm

(14-1/8")

back

exhaust

power supply cord/cable strain relief

35.6 cm (14")

The dryer door extends 35.6 cm (14") from the front of the dryer when fully opened.

68.6cm (27")

Exhaust dimensions

10.2 cm

 

 

 

 

 

 

10.8 cm

 

 

 

 

 

 

 

 

 

 

 

 

(4")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(4-1/4")

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

26 cm

(10-1/4")

left or right side exhaust

supply fuse capacity should be 16A. The dryer must be positioned so that the plug is accessible. If the fitted plug is not used, the electrical connection must be carried out by a competent electrician in accordance with local or national codes.

If the supply cord is damaged, it must be replaced with a specially terminated cord by an authorized service agent or a similarly competent person.

Do not use an adapter.

Do not use an extension cord.

WARNING

Electrical Shock Hazard

Electrical earthing is required on this dryer.

Do not earth to a gas pipe.

Do not change the power supply cord plug. If it does not fit the outlet, have a proper outlet installed by a qualified electrician.

Do not have a fuse in the neutral or earthing circuit.

Do not use an extension cord with this dryer.

Check with a qualified electrician to be sure the dryer is properly earthed.

Do not connect plug end of power supply cord into a live receptacle before connecting power supply cord to dryer terminal block.

Do not reuse old power supply cord.

Failure to follow these instructions could result in death, fire, or serious injury.

If codes permit and an additional earth bond wire is used, it is recommended that a qualified electrician determine that the earth bond, path is adequate.