3.Connect ground wire (green or bare) of power supply cable to external ground conductor screw. Tighten screw.

1

4

 

2

 

 

5

3

6

 

1.External ground conductor screw

2.Green or bare copper wire of power supply cord

3.³⁄₄ in. (1.9 cm) UL listed strain relief

4.Center silver-colored terminal block screw

5.Neutral grounding wire (green/yellow)

6.Neutral wire (white or center wire)

4.Place the hooked end of the neutral wire (white wire) of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. Tighten screw.

5.Place the hooked ends of the other power supply cable wires under the outer terminal block screws (hooks facing right). Squeeze hooked ends together. Tighten screws.

2.Connect neutral wire (white or center wire) of power supply cord to the center, silver-colored terminal screw of the terminal block. Tighten screw.

1

3

2

4

 

5

1.External ground conductor screw

2.Neutral grounding wire (green/yellow)

3.Center silver-colored terminal block screw

4.Neutral wire (white or center wire)

5.³⁄₄ in. (1.9 cm) UL listed strain relief

3.Connect the other wires to outer terminal block screws. Tighten screws.

4.Tighten strain relief screws.

5.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

6.Tighten strain relief screws.

7.Insert tab of terminal block cover into slot of dryer rear panel. Secure cover with hold-down screw.

3-wire connection: Power supply cord

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

2

4

5

1

3

7

6

1.3-wire receptacle (NEMA type 10-30R)

2.3-wire plug

3.Neutral prong

4.Spade terminals with up turned ends

5.³⁄₄ in. (1.9 cm) UL listed strain relief

6.Ring terminals

7.Neutral (white or center wire)

1.Loosen or remove center terminal block screw.

3-wire connection: Direct wire

Use where local codes permit connecting cabinet-ground conductor to neutral wire.

Direct wire cable must have 5 ft (1.52 m) of extra length so dryer can be moved if needed.

Strip 3¹⁄₂ in. (8.9 cm) of outer covering from end of cable. Strip insulation back 1 in. (2.5 cm). If using 3-wire cable with ground wire, cut bare wire even with outer covering. Shape ends of wires into a hook shape.

When connecting to the terminal block, place the hooked end of the wire under the screw of the terminal block (hook facing right), squeeze hooked end together and tighten screw. See example below.

1.Loosen or remove center terminal block screw.

10

Page 10
Image 10
Whirlpool 8533582 manual Loosen or remove center terminal block screw