Whirlpool 8578198 manual Venting Requirements, Plan Vent System

Models: 8578198

1 28
Download 28 pages 7.23 Kb
Page 6
Image 6

Venting Requirements

WARNING

Fire Hazard

Use a heavy metal vent.

Do not use a plastic vent.

Do not use a metal foil vent.

Failure to follow these instructions can result in death or fire.

WARNING: To reduce the risk of fire, this dryer MUST BE EXHAUSTED OUTDOORS.

4" (10.2 cm) heavy metal exhaust vent and clamps must be used. DURASAFE™ vent products are recommended.

DURASAFE™ vent products can be purchased from your dealer or by calling Whirlpool Parts and Accessories. For more information, see the “Assistance or Service” section of this manual.

The dryer exhaust must not be connected into any gas vent, chimney, wall, ceiling, or a concealed space of a building.

Do not use an exhaust hood with a magnetic latch.

Do not install flexible metal vent in enclosed walls, ceilings or floors.

Use clamps to seal all joints. Exhaust vent must not be connected or secured with screws or other fastening devices which extend into the interior of the duct. Do not use duct tape.

IMPORTANT: Observe all governing codes and ordinances.

Improper venting can cause moisture and lint to collect indoors, which may result in:

Moisture damage to woodwork, furniture, paint, wallpaper, carpets, etc.

Housecleaning problems and health problems.

Use a heavy metal vent. Do not use plastic or metal foil vent.

Rigid metal vent is recommended to prevent crushing and kinking.

Flexible metal vent must be fully extended and supported when the dryer is in its final position. Remove excess flexible metal vent to avoid sagging and kinking that may result in reduced airflow.

An exhaust hood should cap the vent to prevent rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

Plan Vent System

Typical installations vent the dryer from the rear of the dryer.

A

B

C

A. Exhaust hood

B. Flexible metal vent or rigid metal vent

C. Elbow

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions provided with the vent system.

AB

A. Over-The-Top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For ordering information see “Assistance or Service.”

Over-The-Top Installation: Part Number 4396028

Periscope Installation (for use with dryer vent to wall vent mismatch):

Part Number 4396037 - for mismatch of 0" (0 cm) to 18" (45.72 cm)

Part Number 4396011 - for mismatch of 18" (45.72 cm) to 29" (73.66 cm)

Part Number 4396014 - for mismatch of 29" (73.66 cm) to 50" (127 cm)

6

Page 6
Image 6
Whirlpool 8578198 manual Venting Requirements, Plan Vent System, Alternate installations for close clearances