19.07.2005 / Page 2 | ADP 4300 WH | Whirlpool Europe |
| S E R V I C E |
Doc. No: 4812 728 11578 | 8511 764 43810 | Customer Service | ||
|
|
|
|
|
Technical data
Dimension |
|
|
Height | 82.0 - 87.0cm | |
Width | 59.7 | cm |
Depth | 55.5 | cm |
Weight | 50 | kg |
Wooden door for Integrable types |
| |
Thickness min. | 16 | mm |
Thickness max. | 20 | mm |
Width min. | 592 | mm |
Width max. | 595 | mm |
Height min. | 515 | mm |
Height max. | 600 | mm |
Weight max. | 5.5 | kg |
Max. stick out over lower |
|
|
edge of appliance door | 92 | mm |
Height of plinth min. | 93 | mm |
Electronic boards |
|
|
Service boards | see spare part list | |
Serial boards | see on the boards itself |
Programmed control board and programing of version , see „Board Service“ and „DATA“ on rating plate of inner door:
UCB | 704812 |
Data set | 704802 |
Basic UCB, not programmed | |
see on the board itself | 4619 727 04651 |
Succession of programs |
|
Programs | see program diagram |
Succession | |
Datas Energy Label |
|
Reference program | P5b |
Energy Performance | B |
Cleaning Performance | B |
Drying Performance | C |
Program information
Start indicator
All programs will be locked after start. Changing the program or finishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position.
Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program.
Water Volume at permanent spray system
Water | Volume | Level |
Regeneration | 0.3 l | 15 mm |
Back rinse 3x | 1.0 l | 60 mm |
Prewash | 4.8 l | 120 mm |
Main wash | 4.2 l | 118 mm |
Intermediate rinse 1 | 4.2 l | 118 mm |
Intermediate rinse 2 | 4.2 l | 118 mm |
Clear rinse | 4.2 l | 118 mm |
Safety/ overflow | 8.5 l | 141 mm |
Measuring the level
Remove the coarse sieve, put in a measuring meter into the sump, measure the hight of the water level.
Detergent max. |
|
|
10 | cm3 | |
40 | cm3 | |
Rinse aid | 135 | cm3 |
6 Dosage steps | 1 - 6 | ml |
Water softener |
|
|
Saltcontainer | 2 | kg |
Resin container | 700 | cm3 |
Regeneration dosage | 300 | cm3 |
Water pressure |
|
|
Inlet pressure | 0.3 - 10 | bar |
Spray pump pressure | 0.3 | bar |
Rotations |
|
|
Spray pump motor | 2800 | RPM |
Drain pump motor | 3000 | RPM |
Spray arm lower | 30 - 40 | RPM |
Spray arm upper | 30 - 40 | RPM |