S E R V I C E
Whirlpool Europe | ADP 4300 WH | 19.07.2005 / Page 3 |
Customer Service | 8511 764 43810 | Doc. No: 4812 728 11578 |
|
|
|
Technical data
Flow rates/ Inlet volume
Flow meter (at 0.3 bar = quantity 1.1 l/min)
| 208 | lmp/l |
Spray pump | 65 | l/min |
Drain pump | 16 | l/min |
Pump height max. | 1.1 | m |
Inlet valve | 4 | l/min |
Spray arm lower | ~ 33 | l/min |
Sprayarm upper | ~ 27 | l/min |
Sprayarm/ Shower top | ~ 8 | l/min |
Electrical base data |
|
|
Voltage | 220/ 240 | V |
Frequency | 50 | Hz |
Total power | 2.0 - 2.2 | kW |
Fuse | 10 | A |
Spray pump motor - permanent spray system | ||
Voltage | 220/ 240 | V |
Power consumption | 80 | W |
Frequency | 50 | Hz |
Resistance | 30 | Ω |
Drain pump motor |
|
|
Voltage | 220/ 240 | V |
Power consumption | 30 | W |
Resistance | 146 | Ω |
Heating - 1 Element system |
|
|
Voltage | 220/ 240 | V |
Power consumption | 1.87/ 2.04 kW | |
Resistance | 24.5 | Ω |
Heating speed | ~ 2.0 | ˚C/min |
Temperature on surface | ~ 115 | ˚C |
Safety thermostat |
|
|
self reset |
|
|
(Temperature of water) | ~ 85 | ˚C |
Fuse | 206 | ˚C |
Water safty options |
|
|
Waterstop system | Electronic aqua control | |
Single electric water inlet valve |
| |
Voltage | 220/ 240 | V |
Frequency | 50/ 60 | Hz |
Resistance | 3.76 | kΩ |
Regenerating valve |
|
|
Voltage | 220/ 240 | V |
Frequency | 50/ 60 | Hz |
Resistance | 3.13 | kΩ |
Coil of dispenser |
|
|
Voltage | 220/ 240 | V |
Frequency | 50/ 60 | Hz |
Resistance | 1.3 | kΩ |
Reed contacts |
|
|
flow meter |
|
|
NTC |
|
|
20 ˚C | 58.1 | kΩ |
25 ˚C | 47.1 | kΩ |
30 ˚C | 38.2 | kΩ |
40 ˚C | 25.4 | kΩ |
50 ˚C | 17.2 | kΩ |
60 ˚C | 11.8 | kΩ |
70 ˚C | 8.3 | kΩ |
80 ˚C | 6 | kΩ |
85 ˚C | 4 | kΩ |
Regeneration |
|
|
Volume | 300 | cm3 |
after wash cycles | depending on the water | |
| softener setting | |
water hardness | 0 - 40 | ˚dh |
| 0 - 10.7 | mmol/l |
| 0 - 107 | ˚Fh |
Salt consumption |
|
|
for regeneration | ~ 77 | g |
Number of cycles |
|
|
with 2 kg salt | ~ 26 |
|