CaringForYourAirConditioner

Annual maintenance

Your air conditioner needs annual maintenance to help ensure steady, top performance through- out the year.

Call the service company recommended by your dealer to:

linspect and clean the coils and condensate water passages.

l Check fan and fan motor.

The compressor is sealed and needs no oiling. Expense of annual inspection is customer’s responsibility.

OR

if you are familiar with electrical appliances, you can do the deaning and maintenance yourself. H you choose to do so, follow these steps:

Electrlcal Shock and

Personal InJury Hazard

l Unplug power cord from receptacle before performlng any maintenance. Be sure no llqukl gets into the motor, electrkal control box or compressor electrical terminals.

l Because your alr wnditlcner weighs from

49.5to 67.5 kg (110 to 166 pounds), lt Is recommended that you have someone help you when you remove and re-Install your unft and that you both use proper llftlng techniques.

l Handle the alr wnditloner with care. Watch out for the sharp metal fins on the front and rear condenser coils.

l Dc not use the collected water for drlnklng purposes. ft Is not sanltsry.

Failure to follow the above precautions could result In electrical shock or personal Injury.

1.Unplug power cord.

2.Remove front panel. (See page 5 for instruc- tions.)

3.Pull control knobs straight off. Remove the control plate.

4.Remove the green ground wire. it is attached with a screw located on the bottom left side. under the control plate. (Save the screw to reattach wire.)

5.Pull out wire handles at bottom and slide air conditioner out of cabinet.

NOTE: The air conditioner is heavy and should be removed by at least two people.

6.Wrap the motor, electrical control box and compressor terminal box in plastic film and make sure no water or other liquid gets inside any of these parts. it could damage the insulation and cause serious mechanical problems.

7.Carefully clean and hose out the base, condenser coils and condensate parts. Clean at least once a year-or more often if the condenser coil and pan collects dirt, sand, leaves, insects or aigae. Also, dean if you detect an odor coming from the air condi- tioner. (A good time to oil the motor is when you already have the cabinet open. See “Oiling the fan motor” on page 7.)

8.Remove plastic film from motor and electrical

patIS.

9.Replace unit in cabinet.

10.Reattach ground wire. Replace control plate and knobs.

11.Replace front panel.

12.Reconnect power supply.

NOTE: it is a good idea to wait 24 hours before starting the unit again. This allows time for ail areas to dry out. The water from rainfall or from normal operation does not harm these compo- nents.

Page 6
Image 6
Whirlpool CA13WQ4 manual CaringForYourAirConditioner, Annual maintenance

CA13WQ4 specifications

The Whirlpool CA13WQ4 is a highly acclaimed air conditioning unit that combines cutting-edge technology with efficient cooling performance. Designed for both residential and commercial use, this model has garnered attention for its robust features and user-friendly characteristics.

One of the standout features of the CA13WQ4 is its energy efficiency. With a high Seasonal Energy Efficiency Ratio (SEER), this air conditioner operates using less energy than older models, helping to reduce electricity bills while maintaining a comfortable indoor environment. This energy efficiency is supported by its advanced compressor technology, which adjusts its speed based on cooling demands, ensuring optimal temperature control without excessive energy consumption.

Another notable aspect of the Whirlpool CA13WQ4 is its quiet operation. The unit is engineered with sound-dampening technology, making it one of the quieter options on the market. This is particularly beneficial for nighttime use or in settings where noise levels need to be minimized, such as bedrooms or office spaces.

The CA13WQ4 also incorporates a multi-speed fan, allowing users to select airflow levels according to their comfort needs. This flexibility ensures that the indoor environment can be customized easily, accommodating various preferences and weather conditions. Additionally, the unit features a programmable thermostat, which enables users to set specific cooling schedules and enhance overall convenience.

Durability is another key characteristic of the Whirlpool CA13WQ4. The unit is built with high-quality materials that withstand outdoor elements, ensuring longevity and reliable performance. Its design includes a corrosion-resistant outdoor coil, which helps prevent wear and tear over time, enhancing the unit’s life span.

The installation process for the CA13WQ4 is straightforward, making it accessible for both professional installers and DIY enthusiasts. Moreover, its sleek design ensures that it can seamlessly blend into various architectural styles while occupying minimal space.

In summary, the Whirlpool CA13WQ4 air conditioning unit stands out for its energy efficiency, quiet operation, and versatile features. With advanced technology, durable construction, and user-friendly controls, it presents an appealing option for anyone seeking a reliable and effective cooling solution. Whether for home use or in commercial settings, the CA13WQ4 is designed to deliver comfort and satisfaction throughout the warmer months.