Whirlpool CEDC392PQ0 manual Plan Vent System, Alternate installations for close clearances

Models: CEDC392PQ0

1 16
Download 16 pages 15.86 Kb
Page 7
Image 7

An exhaust hood should cap the vent to prevent rodents and insects from entering the home.

Exhaust hood must be at least 12" (30.5 cm) from the ground or any object that may be in the path of the exhaust (such as flowers, rocks or bushes, etc.).

If using an existing vent system, clean lint from the entire length of the system and make sure exhaust hood is not plugged with lint. Replace any plastic or metal foil vent with rigid metal or flexible metal vent.

Plan Vent System

Typical installations vent the dryer from the rear of the dryer.

A

B

C

A. Exhaust hood

B. Flexible metal vent or rigid metal vent

C. Elbow

Alternate installations for close clearances

Venting systems come in many varieties. Select the type best for your installation. Two close-clearance installations are shown. Refer to the manufacturer’s instructions provided with the vent system.

AB

A. Over-The-Top installation (also available with one offset elbow)

B. Periscope installation

NOTE: The following kits for close clearance alternate installations are available for purchase. For ordering information see “Assistance or Service.”

Over-The-Top Installation: Part Number 4396028

Periscope Installation (for use with dryer vent to wall vent mismatch):

Part Number 4396037 - for mismatch of 0" (0 cm) to 18" (45.72 cm)

Part Number 4396011 - for mismatch of 18" (45.72 cm) to 29" (73.66 cm)

Part Number 4396014 - for mismatch of 29" (73.66 cm) to 50" (127 cm)

Special provisions for mobile home installations

The exhaust vent must be securely fastened to a noncombustible portion of the mobile home structure and must not terminate beneath the mobile home. Terminate the exhaust vent outside.