Check the

following

before

calling

a serviceman:

 

C.

Unit runs

but

produces

very

Irttle ice:

 

 

 

 

A.

Unit

does

not

run:

 

 

 

 

 

Operation

of

remote

condensrng

unit

in

extremely

 

 

 

 

 

 

 

 

 

 

high

temperatures

(normal

for

ice

production

to

 

1.

Make

sure

service

switch

is positioned

to “on”.

 

be low).

 

 

 

 

 

 

 

 

 

 

2.

Check

fuses in

power

supply

to ice

maker head

 

Lint

or

dirt

blocking

proper

air

flow

through

 

and remote

refrigeration

unit.

 

 

 

finned

condenser

of

air

cooled

condensing

unit

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(check

and

clean),

 

 

 

 

 

 

 

 

 

 

NOTE:

If

green light

on

control

panel

is

lit,

it indicates

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

power

supply

is

okay

 

to ice

making

section.

Separate

 

Check

for

objects

around

condensing

unit

which

 

fuses

 

must

be

checked

 

for

 

the

power

 

to

remote

 

would

obstruct

normal

air

flow.

 

 

 

 

 

 

refrigeration

 

section.

Fuses

inside

control

panel

are

for

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

low

voltage

circuits

only.

 

 

 

 

 

 

 

 

 

D.

Red

light

 

on

control

panel

lit:

 

 

 

 

 

 

 

B.

Unit

runs

but

produces

no

ice:

 

 

 

 

 

 

 

 

I,

Whenever

the

red

light

is

lit,

it

is an

indication

of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

an

abnormally

long

harvest

cycle.

Long

harvest

 

1.

Check

all

mercury

 

switches

positioned

 

over

water

 

cycles

 

are

generally

caused

 

by

ice

slabs

not

 

 

trough.

Arms

must

be

vertical.

If

switch

arms

are

 

releasing

properly

and

may

indicate

the

machine

 

 

not

vertical,

check

for

bind.

Check

position

of

 

needs

to

be

cleaned.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

switch

capsule

in

bracket

against

 

sketch

on

NOTE:

The

red

indicator

also

lights

up

whenever

the

 

 

support

rail.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

service switch is in the “clean”position.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2.

Turn

service

switch

 

to

 

“off”

position

for

one

2.

Call

a qualified

serviceman

to

check

the

machine

if

 

 

minute and then reset to “on” position.

 

 

 

 

 

 

 

 

 

the

above suggestions

do not

remedy

the

problem.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

%2%xralrtp1

 

Benton

Harbor,

Michigan.

Manufacturer

of Automatic

Washers,

WhirlpoolIOR~CCA~lON

Wringer

Washers,

Clothes

Dryers,

Freezers,

Refrigerators,

and

Surface

Units,

Ranges,

Food

Waste

Disposers,

Central

 

Refrigerator-freezers,

 

Ice

Makers,

Dishwashers,

Built-In

Ovens

 

Vacuum

Systems.

 

Dehumidifiers,

Air

Conditioners.

 

 

Printed in U.S.A. Whirlpool Corporate Printing Services

Part No. 585102 Rev. A