Cabinet Dimensions

27" (68.6 cm) and 30" (76.2 cm) Ovens

 

A

 

B

F

D

 

E

 

C

Electrical Requirements

If codes permit and a separate ground wire is used, it is recommended that a qualified electrical installer determine that the ground path and wire gauge are in accordance with local codes.

Check with a qualified electrical installer if you are not sure the oven is properly grounded.

This oven must be connected to a grounded metal, permanent wiring system.

Be sure that the electrical connection and wire size are adequate and in conformance with the National Electrical Code, ANSI/NFPA 70-latest edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1 and C22.2 No. O-M91-latest edition, and all local codes and ordinances.

A copy of the above code standards can be obtained from:

National Fire Protection Association

One Batterymarch Park

Quincy, MA 02269

CSA International

8501 East Pleasant Valley Road

27" (68.6 cm) models

A. 27" (68.6 cm) min. cabinet width

B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door

C. 19¹⁄₄" (48.9 cm) bottom of cutout to floor

D. 25¹⁄₂" (64.8 cm) cutout width

E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door

F. 41¹⁄₄" (104.8 cm) cutout height

30" (76.2 cm) models

A. 30" (76.2 cm) min. cabinet width

B. 1" (2.5 cm) top of cutout to bottom of upper cabinet door

C. 19¹⁄₄" (48.9 cm) bottom of cutout to floor

D. 28¹⁄₂" (72.4 cm) cutout width

E. 1¹⁄₂" (3.8 cm) min. bottom of cutout to top of cabinet door

F. 41¹⁄₄" (104.8 cm) cutout height

Cleveland, OH 44131-5575

Electrical Connection

To properly install your oven, you must determine the type of electrical connection you will be using and follow the instructions provided for it here.

Oven must be connected to the proper electrical voltage and frequency as specified on the model/serial number rating plate. The model/serial number rating plate is located at the bottom of the right-hand mounting rail. See the following illustration.

Cabinet Side View

 

 

A

 

A

 

 

B

 

E

C

A. Model/serial number plate

 

D

 

 

 

Models rated from 7.3 to 9.6 kW at 240 volts (5.5 to 7.2 kW

 

 

at 208 volts) require a separate 40-amp circuit. Models rated

 

 

at 7.2 kW and below at 240 volts (5.4 kW and below at

 

 

208 volts) require a separate 30-amp circuit.

A. 23¹⁄₄" (59.1 cm) min. cutout depth B. 23" (58.4 cm) recessed oven depth C. Oven front

D. Recessed oven E. Cabinet

A circuit breaker is recommended.

Connect directly to the circuit breaker box (or fused disconnect) through flexible, armored or nonmetallic sheathed, copper cable (with grounding wire). See “Make Electrical Connection” section.

Flexible conduit from the oven should be connected directly to the junction box.

Do not cut the conduit. The length of conduit provided is for serviceability of the oven.

A UL listed or CSA approved conduit connector must be provided.

3

Page 3
Image 3
Whirlpool Electric Built-In Microwave/Oven Electrical Requirements, Cabinet Dimensions, Electrical Connection