Using Your Freezer

Continued

Light shield

The interior light

Electrical Shock Hazard

Before removing a light bulb, either unplug the freezer or disconnect the electricity leading to the freezer at the main power supply. Shock and injury can occur if elec- tricity remains connected.

To replace the light:

1.Disconnect freezer from power supply.

2.Remove the light shield from the side of the control panel. Depress the back of the shield to release the tabs, then pull away.

3.Replace the bulb with a 40-watt appliance bulb.

4.Replace the light shield. Insert the shield

tabs in the slots, then press the shield to snap into place.

5.Reconnect power supply.

The signal light

The signal light automatically warns of any unexpected power failure.

If the signal light is not glowing, immediately check for power interruption, an unplugged power cord or a burned out signal light.

To replace signal light:

1.Disconnect freezer from power supply.

2.Open the freezer door.

3.Push out signal light from behind, then unplug burned out light. Replace with a new one. Signal light can be ordered from your Whirlpool dealer, Part No. 1103639.

4.Close freezer door and reconnect power supply.

Page 6