ELECTRICAL REQUIREMENTS
IMPORTANT: The range must be electrically grounded in accordance with | If codes permit and a separate ground wire is used, it is recommended that a | ||||||||||
local codes and ordinances, or in the absence of local codes, with the | qualified electrical installer determine that the ground path is adequate. | ||||||||||
National Electrical Code, ANSI/NFPA 70 or Canadian Electrical Code, CSA | ● A 120 volt, 60 Hz., AC only, | ||||||||||
C22.1. | |||||||||||
| recommended that a separate circuit serving only this range be provided. | ||||||||||
| ● Electronic ignition systems operate within wide voltage limits, but proper | ||||||||||
| grounding and polarity are necessary. Check that the outlet provides | ||||||||||
|
| ||||||||||
CABINET OPENING DIMENSIONS |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Cabinet opening dimensions shown are for 25" (64.0 cm) countertop |
|
|
|
|
|
|
|
|
|
|
|
depth, 24" (61.0 cm) base cabinet depth and 36" (91.4 cm) countertop |
|
|
|
|
|
|
|
|
|
|
|
height. |
|
|
|
|
|
|
|
|
|
|
|
IMPORTANT: If installing a range hood or microwave hood |
|
|
|
| B |
|
|
|
| D |
|
combination above the range, follow the range hood or microwave |
|
|
|
|
|
|
|
|
| ||
hood combination installation instructions for dimensional clearances |
|
|
|
| C |
|
|
|
|
|
|
above the cooktop surface. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
Range may be installed with zero clearance to combustible |
|
|
|
|
|
|
|
|
|
|
|
construction at the rear and on the sides below the cooktop. | A | E |
|
|
|
|
|
| |||
|
|
|
|
|
| ||||||
|
|
|
|
|
| ||||||
A. 18" (45.7 cm) upper cabinet to countertop |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| |
B. 13" (33.0 cm) upper cabinet depth |
|
|
| F |
|
|
|
|
|
|
|
C. 30" (76.2 cm) min. opening width |
|
|
| J | I | G | |||||
D. For minimum clearance to the top of the cooktop, see NOTE. |
|
|
|
| K |
| |||||
E. 30" (76.2 cm) min. opening width |
|
|
|
| L |
| |||||
|
|
|
|
|
| ||||||
F. 3" (7.6 cm) min. clearance from both sides of the range to the side |
|
|
|
|
|
|
|
|
|
|
|
wall or other combustible material. |
|
|
|
|
| H |
| ||||
G. Cabinet door or hinges should not extend into the cutout. |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
H. 3" (7.6 cm) distance from wall |
|
|
|
|
|
|
|
|
|
|
|
I. 1½" (3.8 cm) min. from right side cabinet |
|
|
|
|
|
|
|
|
|
|
|
J. 8" (20.3 cm) width |
|
|
|
|
| 8½" |
| ||||
K. 7" (17.8 cm) min. from floor |
|
|
|
|
|
| |||||
|
|
|
|
| (21.6 cm) |
| |||||
L. 2" (5.1 cm) min. from floor |
|
|
|
|
|
| |||||
|
|
|
|
|
|
|
|
|
|
| |
Drill on centerline 1¹⁄₄" (3.1 cm) from rear wall for gas supply |
|
|
|
|
|
|
|
|
|
| 14" |
line. |
|
|
|
|
|
|
|
|
|
| |
|
|
|
|
|
|
|
|
|
|
| (35.6 cm) |
**Gas lines must be installed within the shaded area to ensure proper alignment of this oven with cabinets.
***Electrical plugs must be installed within the shaded area to ensure proper alignment of this oven with cabinets.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal cabinet is covered by not less than ¹⁄₄" (0.64 cm) flame retardant millboard covered with not less than No. 28 MSG sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 0.020" (0.5 mm) copper.
30" (76.2 cm) minimum clearance between the top of the cooking platform and the bottom of an uncovered wood or metal cabinet.
1½" | 2¼" (5.7 cm) |
(3.8 cm) |
1¼"*
(3.1 cm)
8½" (21.6 cm)** gas line location
|
| Page 2 of 2 |
Because Whirlpool Corporation policy includes a continuous commitment to improve | Dimensions are for planning purposes only. For complete details, see Installation | Ref. W10526071A |
our products, we reserve the right to change materials and specifications without notice. | Instructions packed with product. Specifications subject to change without notice. | 2/13/13 |