Recessed or closet installation - Dryer on pedestal
|
|
|
| 14" max. | |
|
|
|
| (35.6 cm) | |
|
|
|
| 18" min. | |
|
|
|
| (45.72 cm) | |
0" | 27" | 0" | 0" | 31½" | 0" |
(0 cm) | (68.6 cm) | (0 cm) | (0 cm) | (80 cm) | (0 cm) |
AB
A. Recessed area
B. Side view - closet or confined area
Minimum installation spacing for cabinet installation
■The dimensions shown are for the minimum spacing allowed.
■For cabinet installation, with a door, minimum ventilation openings in the top of the cabinet are required.
7" (17.8 cm) | 7" (17.8 cm) |
9"
(22.9 cm)
0" | 31¹ " | 0" | 0" | 27" | 0" |
(0 cm) | (80.0 cm) | (0 cm) | (0 cm) | (68.6 cm) (0 cm) |
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The install- ation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280).
Mobile home installations require:
■Metal exhaust system hardware which is available for purchase from your dealer.
■Mobile home Installation Kit Part Number 346764. See “Tools and Parts” section for ordering information.
■Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
■
GROUNDING INSTRUCTIONS
■For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock. Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
7