PRODUCT DATA SHEETS

Base Grille Water Filtration System

Model WF-L200V Capacity 200 Gallons (757 Liters)

Model WF-NL120V Capacity 120 Gallons (454 Liters)

System tested and certified by NSF International against NSF/ANSI Standard 53 for the reduction of Lead, Mercury, Benzene, p-dichlorobenzene, O-Dichlorobenzene, Toxaphene, Ethyl Benzene, 1,2,4-trichlorobenzene and against NSF/ANSI Standard 42 for the reduction of Chlorine Taste and Odor and Particulate Class III.

This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in ANSI/NSF 42/53.

Substance Reduction

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Aesthetic Effects

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Chlorine Taste/Odor

≥50%

1.9 mg/L

2.0 mg/L ± 10%

0.07 mg/L

0.06 mg/L

>75%

>75%

Particulate Class lll*

≥85%

49333/mL

At least 10,000 particles/mL

640/mL**

312/mL

98.7%

99.0%

 

 

 

 

 

 

 

 

Contaminant

NSF Reduction

Average

Influent Challenge

Maximum

Average

Minimum%

Average%

Reduction

Requirements

Influent

Concentration

Effluent

Effluent

Reduction

Reduction

 

 

 

 

 

 

 

 

Lead:@ pH 6.5

0.01mg/L

0.14 mg/L†

0.15 mg/L ± 10%

0.0014 mg/L

0.0011 mg/L

99.00%

99.21%

Lead: @ pH 8.5

0.01mg /L

0.15 mg/L†

0.15 mg /L ± 10%

0.0069 mg/L

0.0042 mg/L

95.40%%

97.20%

 

 

 

 

 

 

 

 

Mercury: @ pH 6.5

0.002 mg/L

0.0059 mg/L

0.006 mg/L ± 10%

0.0009 mg/L

0.0004 mg/L

84.74%

93.22%

Mercury: @ pH 8.5

0.002 mg/L

0.0054 mg/L

0.006 mg /L ± 10%

0.0007mg /L

0.00043 mg/L

87.03%

92.03%

 

 

 

 

 

 

 

 

Benzene

0.005 mg/L

0.0157 mg/L

0.015 mg/L ± 10%

0.002 mg/L

0.00083 mg/L

87.26%

94.71%

 

 

 

 

 

 

 

 

p-dichlorobenzene

0.075 mg/L

0.210 mg/L

0.225 mg/L ± 10%

0.0005 mg/L

0.0005 mg/L

99.76%

99.76%

 

 

 

 

 

 

 

 

O-Dichlorobenzene

0.60

1.84

1.8 ± 10%

0.20

0.0418

89.13

97.73

 

 

 

 

 

 

 

 

Toxaphene

0.003

0.0143

0.015 ± 10%

0.0012

0.0010

91.60

93.00

 

 

 

 

 

 

 

 

Ethyl Benzene

0.70

2.00

2.1 ± 10%

0.40

0.085

80.00

95.75

 

 

 

 

 

 

 

 

1,2,4- trichlorobenzene

0.07

0.232

0.21 ± 10%

0.0041

0.0016

98.23

99.31

 

 

 

 

 

 

 

 

Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F (17.2°C).

■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.

■Model WF-L200V:The filter monitor system measures the amount of water that passes through the filter and alerts you to replace the filter. When 90% of the filter’s rated life is used, the filter indicator light changes from green to yellow. When 100% of the filter’s rated life is used, the filter indicator light changes from yellow to red, and it is recommended that you replace the filter. Use replacement filter L200V / NL120V, part #4396701. 2007 suggested retail price of $34.99 U.S.A./ $45.99 Canada. Prices are subject to change without notice.

Model WF-NL120V:Change the water filter every

6 months. Use replacement filter L200V / NL120V, part #4396701. 2007 suggested retail price of $34.99 U.S.A./ $45.99 Canada. Prices are subject to change without notice.

■The product is for cold water use only.

■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.

■Refer to the front cover or “Accessories” section for the Manufacturer’s name, address and telephone number.

■Refer to the “Warranty” section for the Manufacturer’s limited warranty.

Application Guidelines/Water Supply Parameters

Water Supply

City or Well

Water Pressure

30 - 120 psi (207 - 827 kPa)

Water Temperature

33° - 100°F (0.6° - 37.8°C)

Service Flow Rate

0.5 GPM (1.9 L/min.) @ 60 psi

*Class Ill particle size: > 5 to < 15 um

**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.

†These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions. ® NSF is a registered trademark of NSF International.