Undercounter Dishwasher

Undercounter Dishwasher

PRODUCT MODEL NUMBERS

GU3100XTV

Requirements:

120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply

Copper wire only, 2 wire with ground

Recommended:

Time-delay fuse or circuit breaker

Separate circuit

Direct Wire Connection:

Use flexible, armored or nonmetalic sheathed, copper wire with grounding wire that meets the wiring requirements for your home and local codes and ordinances.

Use strain relief method provided with house wiring junction box or install a UL-listed/CSA-certified clamp connector to the house wiring junction box. If using conduit, use a UL-listed/CSA- certified conduit connector.

Power Supply Cord Connection:

Use Power Supply Cord Kit (Part Number 4317824) marked for use with dishwashers. Kit contents include:

Voltex, Inc., UL listed 16 gauge 3-wire power supply cord with 3 prong grounding plug

Neer C-500 ⁷⁄₈" strain relief

3 wire connectors

Part Number 302797 grommet

Follow the kit instructions for installing the power supply cord.

NOTE: Power supply cord must plug into a mating three prong, grounded outlet, located in the cabinet next to the dishwasher opening. Outlet must meet all local codes and ordinances.

IMPORTANT: If you plan to install a garbage disposal, an additional separate 120-volt, 60 Hz, AC-only, 15- or 20-amp fused electrical supply is required.

Water Supply Requirements:

A hot water line with 20-120 psi (138-862 kPa) water pressure.

120°F (49°C) water temperature at dishwasher.

³⁄₈" O.D. copper tubing with compression fitting or flexible braided water supply line.

NOTE: ¹⁄₂" minimum plastic tubing is not recommended.

90º elbow with 3⁄8" N.P.T. external pipe threads on one end.

IMPORTANT: Do not solder within 6" (15.2 cm) from water inlet valve.

Drain Requirements:

Use the new drain hose supplied with your dishwasher. NOTE: If a longer drain hose is required:

Use a new drain hose with maximum length of 10 ft

(3 m) that meets all current AHAM/IAPMO test standards

Use a new drain hose that is resistant to heat and detergent

Use a new drain hose that fits the 1" (2.5 cm) drain connector on the dishwasher.

Connect drain hose to waste tee or disposal inlet above drain trap in house plumbing.

Connect drain hose to house plumbing 20" (50.8 cm) minimum above the floor.

NOTE: It is recommended that the drain hose either be looped up and securely fastened to the underside of the counter, or be connected to an air gap.

Use a drain air gap if the drain hose is connected to house plumbing lower than 18" (45.7 cm) above the subfloor or floor.

Drain Air Gap:

Use ¹⁄₂" (1.3 cm) minimum I.D. drain line fittings.

NOTE: Do not connect drain lines from other devices to the dishwasher drain hose.

MINIMUM CLEARANCES

Check location where the dishwasher will be installed. the location must provide:

Easy access to water, electricity and drain.

Convenient access for loading and unloading dishes. Corner locations require 2" (5.1 cm) minimum clearance between the side of the dishwasher door and the wall or cabinet.

A minimum of 25⁵⁄₈" (65.1 cm) is required in front of the dishwasher to allow the door to open fully.

C

B

AD

A. 2" (5.1 cm) minimum clearance

C. Countertop

for door opening

D. 25⁵⁄₈" (65.1 cm) minimum

B.Dishwasher

Square opening for proper orientation.

Cabinet front perpendicular to floor.

Level floor. If the floor at the front of the dishwasher is not level with the rear of the opening, shims may be needed to level the dishwasher.

NOTE: To avoid shifting during dishwasher operation, shims must be securely attached attached to the

Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation

Ref. W10167841-D-WH

Instructions packed with product. Specifications subject to change without notice.