14.02.2002 / Page 2 | ADG 6556 IXM | Whirlpool Europe |
| S E R V I C E |
Doc. No: 4812 718 17313 | 8542 556 10740 | Customer Service | ||
|
|
|
|
|
Technical data
Dimension
Height | 82.0 - 87.0 cm | |
Width | 59.7 | cm |
Depth | 55.5 | cm |
Weight | 50 | kg |
Wooden door for Integrable types |
| |
Thickness min. | 16 | mm |
Thickness max. | 20 | mm |
Width min. | 592 | mm |
Width max. | 595 | mm |
Height min. | 515 | mm |
Height max. | 600 | mm |
Weight max. | 5.5 | kg |
Max. stick out over lower |
|
|
edge of appliance door | 92 | mm |
Height of plinth min. | 93 | mm |
Electronic boards |
|
|
Service boards | see spare part list | |
Serial boards | see on the boards itself | |
DUB | 4619 724 06661 |
Programing of version and programmed control board, see „Service“ and „Data set“ on rating plate of inner door:
CB programmed | 442241 |
Data set | 442231 |
Basic control board, not programmed see on the | |
board itself | 4619 724 17411 |
Succession of programs |
|
Programs | see program diagram |
Succession | |
Datas Energy Label |
|
Reference program | A5b |
Energy Performance | B |
Cleaning Performance | A |
Drying Performance | B |
Options
Zone washing
Delay function
Program information
Start indicator
Pre wash
Main wash
Drying
End
All programs will be locked after start. Changing the program or finishing the program will be possible only after pressing the start button for longer then 1.5 sec. (Break by customer)
A switching off the appliance or unplug the appliance for a while, this will frozen the program step and later on, the program continuos on the same position.
Exception: Switching off the appliance or unplug the appliance during the drying phase, this will lead directly to the end of the program.
Water Volume at alternating spray system
Volume at alternating spray system (same level when selected zone washing as in the normal programs)
Water | Volume | Level |
Regeneration | 0.3 l | 15 mm |
Back rinse 3x | 1.0 l | 60 mm |
Prewash | 3.9 l | 120 mm |
Main wash | 3.2 l | 118 mm |
Intermediate rinse 1 | 3.2 l | 118 mm |
Intermediate rinse 2 | 3.2 l | 118 mm |
Clear rinse | 3.2 l | 118 mm |
Safety/ overflow | 8.5 l | 141 mm |
Measuring the level
Remove the coarse sieve, put in a measuring meter into the sump, measure the hight of the water level.
Detergent max. |
|
|
10 | cm3 | |
40 | cm3 | |
Rinse aid | 135 | cm3 |
6 Dosage steps | 1 - 6 | ml |
Water softener |
|
|
Saltcontainer | 2 | kg |
Resin container | 900 | cm3 |
Regeneration dosage | 300 | cm3 |