S E R V I C E
Technical data
Whirlpool Europe | ADG 6556 IXM | 14.02.2002 / Page 3 |
Customer Service | 8542 556 10740 | Doc. No: 4812 718 17313 |
|
|
|
Water pressure |
|
|
Inlet pressure | 0.3 - 10 | bar |
Spray pump pressure | 0.3 | bar |
Rotations |
|
|
Spray pump motor | 2800 | RPM |
Drain pump motor | 3000 | RPM |
Spray arm lower | 30 - 40 | RPM |
Spray arm upper | 30 - 40 | RPM |
Spray arms, turning rhythm at alternating spray system
Turning starts every time with the upper spray arm
Pre wash Lower arm ~3min, Upper arm ~1min Main wash Lower arm ~3min, Upper arm ~5min Intermediate rinse
Lower arm ~2min, Upper arm ~2min Final rinse Lower arm ~2min, Upper arm ~2min Service Test program
Lower arm ~30sec, Upper arm ~30sec
Remark: When switching of the main switch or interrupt the mains during the Test Program runs, then the alternating of the spray arms change in the test program to the rhythm of main wash 5/3 min.
Important: To leaf the Test program is possible by made a break by customer (pushing the start button for 1.5 sec.)
After finishing the test program (End LED shines and/or Start LED goes of) must the appliance be switched off.
If this will not be done, then the next normal wash will be made with the frequency of the Service Test Program ~30/30sec.
Flow rates/ Inlet volume |
|
|
Flow meter (at 0.3 bar |
|
|
= quantity 1.1 l/min) | 208 | lmp/l |
Spray pump | 45 - 65 | l/min |
Drain pump | 16 | l/min |
Pump height max. | 1.1 | m |
Inlet valve | 4 | l/min |
Spray arm lower | ~ 33 | l/min |
Sprayarm upper | ~ 27 | l/min |
Shower top | ~ 8 | l/min |
Electrical base data |
|
|
Voltage | 220/ 230 | V |
Frequency | 50 | Hz |
Total power | 2.0 - 2.2 | kW |
Fuse | 10 | A |
Spray pump motor alternating spray system | ||
Voltage | 220/ 240 | V |
Power consumption | 125 | W |
HI | 79 | Ω |
HA | 60 | Ω |
Capacitor | 4 | μ F |
Drain pump motor |
|
|
Voltage | 220/ 240 | V |
Power consumption | 30 | W |
Resistance | 146 | Ω |
Heating |
|
|
1 Element system |
|
|
Voltage | 220/ 230 | V |
Power consumption | 1.87/ 2.04 kW | |
Resistance | 24.5 | Ω |
Heating speed | ~ 2.0 | ˚C/min |
Temperature on surface | ~ 115 | ˚C |
Safety thermostat |
|
|
self reset |
|
|
(Temperature of water) | ~ 85 | ˚C |
Fuse | 206 | ˚C |
Potentiometer |
|
|
Points of meassurement: | 1(black) to 2 (middle) | |
Position 0 | 0.0 | kΩ |
Position 1 | 0.5 | kΩ |
Position 2 | 1.0 | kΩ |
Position 3 | 1.4 | kΩ |
Position 4 | 1.8 | kΩ |
Position 5 | 2.3 | kΩ |
Position 6 | 2.6 | kΩ |
Water valves |
|
|
Single electric inlet valve |
|
|
Voltage | 220/ 240 | V |
Frequency | 50/ 60 | Hz |
Resistance | 3.76 | kΩ |