120-Volt Electric Compact Dryer
PRODUCT MODEL NUMBERS
LDR3822P
OVERALL DIMENSIONS
Electrical:
Exhaust venting: Exhaust your dryer to the outside.
*Most installations require a minimum
*20 3 4" (52.7 cm)
31" † (78.7 cm)
23 7 8"
(60.6 cm)
†Height with caster is 32¹⁄₂" (82.6 cm)
RECESSED AREA AND CLOSET INSTALLATION
Recessed or closet installation - Dryer only | Recessed or closet installation - Stacked |
AB
A. Side view - closet or confined area B. Recessed area
Closet confined area
For closet installation with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent air openings are acceptable.
|
| in. |
|
| in. |
A | B | C |
A. Recessed area
B. Side view - closet or confined area C. Closet door with vents
EXHAUST VENTING
| 4" |
| (10.2 cm) |
| Box hood style |
4" |
|
(10.2 cm) | 2.5" |
| (6.4 cm) |
4" |
|
(10.2 cm) | Angled style |
Louvered style |
1.Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible. Bend vent gradually to avoid kinking. Avoid 90° turns when possible.
2.Determine vent length.
The maximum length of the exhaust system depends upon:
• The type of vent (rigid metal or flexible metal).
Number of | Type of | Box or | Angled |
90° turns | vent | louvered | hoods |
or elbows |
| hoods |
|
|
|
|
|
0 | Rigid metal | 36 ft (11 m) | 26 ft (7.9 m) |
| Flexible metal | 28 ft (8.5 m) | 22 ft (6.7 m) |
|
|
|
|
1 | Rigid metal | 26 ft (7.9 m) | 16 ft (4.9 m) |
| Flexible metal | 18 ft (5.5 m) | 12 ft (3.7 m) |
|
|
|
|
2 | Rigid metal | 16 ft (4.9 m) | 6 ft (1.8 m) |
| Flexible metal | 8 ft (2.8 m) | 2 ft (0.6 m) |
•The number of elbows used.
•Type of hood.
See the exhaust vent length chart that matches your hood type for the maximum vent lengths you can use.
3. Determine the number of elbows you will need.
IMPORTANT: Do not use vent runs longer than specified in the Vent Length Chart.
In the column listing the type of metal vent you are using (rigid metal or flexible metal), find the maximum length of metal vent on the same line as the number of elbows.
Because Whirlpool Corporation policy includes a continuous commitment to improve our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation | Ref. 8562113 |
Instructions packed with product. Specifications subject to change without notice. |