INSTALLATION REQUIREMENTS
Tools and Parts
Gather the required tools and parts before starting installation. Read and follow the instructions provided with any tools listed here.
Tools needed
■Level
■Drill with 1¼" (3.0 cm), ¹⁄₈" (3.2 mm), and ⁵⁄₁₆" (7.9 mm) drill bits
■Pencil
■Wire stripper or utility knife
■Tape measure or ruler
■Pliers
■Caulking gun and weatherproof caulking compound
■Vent clamps
■Jigsaw or keyhole saw
■
■Metal snips
■Phillips screwdriver
■Metric hex key set
Parts needed
■Home power supply cable
■½" (12.7 mm) UL listed or CSA approved strain relief
■3 UL listed wire connectors
For vented installations, you will also need:
■1 wall or roof cap
■Metal vent system
For non-vented (recirculating) installations, you will also need:
■Recirculation Kit Part Number W10294733 for
■6" (15.2 cm) dia. round metal vent duct - length required is determined by ceiling height.
Parts supplied
Remove parts from packages. Check that all parts are included.
■Hood canopy assembly with blower, vent transition, light bulb and canopy glass already installed
■Metal grease filter
■Vent cover support bracket
■Mounting template
■
■4 - 4 x 8 screws
■6 - 5 x 45 mm mounting screws
■2 - 8 x 40 mm wall anchors
■4 - 10 x 50 mm wall anchors
■T10 Torx®† adapter
■T20® Torx®† adapter
†®TORX and T20 are registered trademarks of Saturn Fasteners, Inc.
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Have a qualified technician install the range hood. It is the installer's responsibility to comply with installation clearances specified on the model/serial rating plate. The model/serial rating plate is located behind the left filter on the rear wall of the vent hood.
Canopy hood location should be away from strong draft areas, such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical Requirements” section.
The canopy hood is factory set for venting through the roof or wall. For
All openings in ceiling and wall where canopy hood will be installed must be sealed.
For Mobile Home Installations
The installation of this range hood must conform to the Manufactured Home Construction Safety Standards, Title 24 CFR, Part 328 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD, Part 280) or when such standard is not applicable, the standard for Manufactured Home Installation 1982 (Manufactured Home Sites, Communities and Setups) ANSI A225.1/NFPA 501A, or latest edition, or with local codes.
Product Dimensions
10⁷⁄₈"
(27.6 cm) | 13³⁄₁₆" | ||
(33.5 cm) | |||
|
| ||
|
|
| |
|
|
|
20" |
|
|
(50.8 cm) | 30" | (76.2 cm) or |
| 36" | (91.4 cm) |