Whirlpool RBS277PV Electrical Connection Options Chart, WireCable from Home Power Supply

Models: RBS277PV

1 16
Download 16 pages 41.81 Kb
Page 6
Image 6
Electrical Connection Options Chart

3.Remove junction box cover, if it is present.

4.Install a UL listed or CSA approved conduit connector to the junction box.

A If your home has:Go to section:

A. UL listed or CSA approved conduit connector

5.Route the flexible conduit from the oven to the junction box through a UL listed or CSA approved conduit connector.

6.Tighten screws on conduit connector.

7.See “Electrical Connection Options Chart” to complete installation for your type of electrical connection.

Electrical Connection Options Chart

If your home has:

Go to section:

4-wire

4-wire Cable from Home

 

Power Supply

 

½"

 

(1.3 cm)

3-wire

3-wire Cable from Home

 

Power Supply

1.Connect the 2 black wires (B) together using a UL listed wire connector.

2.Connect the 2 red wires (C) together using a UL listed wire connector.

3.Untwist white wire from green (or bare) ground wire coming from the oven.

4.Connect the 2 white wires (F) together using a UL listed wire connector.

5.Connect the green (or bare) ground wire (H) from the oven cable to the green (or bare) ground wire (in the junction box) using a UL listed wire connector.

6.Install junction box cover.

3-Wire Cable from Home Power Supply - U.S. Only

IMPORTANT: Use the 3-wire cable from home power supply where local codes permit a 3-wire connection.

A

 

B

 

C

G

 

H

D

E

I

F 3-Wire Cable from Home Power Supply - U.S. Only

½"

(1.3 cm)

4-Wire Cable from Home Power Supply

IMPORTANT: Use the 4-wire cable from home power supply in the U.S. where local codes do not allow grounding through neutral, New Branch circuit installations (1996 NEC), mobile homes and recreational vehicles, new construction and in Canada.

A

B

 

 

 

E

 

 

 

F

 

 

 

G

 

 

 

C

H

D

I

A. Cable from home power supply

F. White wires

B. Black wires

G. UL listed wire connectors

C. Red wires

H. Green (or bare) ground wires

D. 4-wire flexible conduit from

I. UL listed or CSA approved

oven

conduit connector

E. Junction box

 

A. Cable from home power supply

F. 4-wire flexible conduit from

B. Junction box

oven

C. Black wires

G. Red wires

D. White wires

H. UL listed wire connectors

E. Green (or bare) ground wire

I. UL listed or CSA approved

(from oven)

conduit connector

1.Connect the 2 black wires (C) together using a UL listed wire connector.

2.Connect the 2 white wires (D) and the green (or bare) ground wire (of the oven cable) using a UL listed wire connector.

3.Connect the 2 red wires (G) together using a UL listed wire connector.

4.Install junction box cover.