PRODUCT MODEL NUMBERS OVERALL DIMENSIONS

VENTING REQUIREMENTS

RH2330XJ

RH2336XJ

RH2630XJ

Electrical: 120-volt, 60-Hz, AC-only, 15-amp. electrical

supply. Use copper wire only. A time-delay fuse or circuit

breaker and separate circuit is recommended.

®Range Hood – 24" (58cm), 30" (76.2 cm), 36" (91.4 cm)
Because Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specifications without notice.Dimensions are for planning purposes only. For complete details, see InstallationInstructions packed with product. Specifications subject to change without notice.Ref. W1011241902-13-0823-7/8" (60.6 cm) – 24" (61.0 cm) model29-7/8" (75.9 cm) – 30" (76.2 cm) model35-7/8" (91.1 cm) – 36" (91.4 cm) model7-1/2" (19.1 cm)2" (5.1 cm)1-1/2" (3.8 cm)1" (2.5 cm)1-1/2" (3.8 cm)6" (15.2 cm)9" (22.9 cm)12" (30.5 cm)3/4" (1.9 cm)3/8" (9.5 mm)17-1/2" (44.5 cm)3-1/4" x 10" (8.3 x 25.4 cm) vent system3-1/4" x 10" (8.3 x 25.4 cm) vent systemMaximum length = 35 ft. (10.7 m)1 - 90° elbow = 5 ft. (1.5 m)8 ft. (2.4 m) straight = 8 ft. (2.4 m)1 - wall cap = 0 ft. (0 m)Length of 3-1/4" x 10" (8.3 x 25.4 cm) system = 13 ft. (3.9 m)Note:Flexible vent is not recommended
3-1/4" x 10"
(8.3 x 25.4 cm)
90° elbow =
5 ft.(1.5 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
flat elbow =
12 ft.(3.7 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
wall cap =
0 ft.(0 m)
2 ft.
(0.6 m)
6 ft.( 1.8 m) wall cap
3-1/4" x 10"
(8.3 x 25.4 cm)
elbow
Maximum length = 35 ft. (10.7 m)1 - 90° elbows = 5 ft.(1.5 m)8 ft. (2.4 m) straight = 8 ft.(2.4 m)1 - wall cap = 0 ft.(0 m)Length of 7" (17.8 cm) system = 13 ft.(3.9 m)Note:Flexible vent is not recommended6" (15.2 cm) vent system
3-1/4" x 10"
(8.3 x 25.4 cm) to
6" (15.2 cm) =
4.5 ft.(1.4 m)
90° elbow =
5 ft.(1.5 m)
45° elbow =
2.5 ft.(0.8 m)
3-1/4" x 10"
(8.3 x 25.4 cm)
to 6" (15.2 cm)
90° elbow =
5 ft.(1.5 m)
6" (15.2 cm)
wall cap =
0 ft.(0 m)
elbow wallcap6 ft.(1.8 m)2 ft.(0.6 m)6" (15.2 cm) vent system
36" (91.4 cm)
base cabinet
height
24" (61.0 cm ) min.
30" (76.2 cm)
suggested max.
bottom of hood to
cooking surface 13" (33 cm)
cabinet depth
18" (45.7 cm) min.
24" (61 cm)
suggested max.
bottom of cabinet
to cooking
surface
24" (61.0 cm) or
30" (76.2 cm) or
36" (91.4 cm)
min.cabinet
opening width

CABINET OPENING DIMENSIONS

Roof Venting Wall Venting
A.6" (15.2 cm) round vent or a (8.3 x 25.4 cm) vent through roof B.Round vent: use 6" (15.2 cm) round damper (purchased separately)C.18" (45.7 cm) to 24" (61.0 cm) above cooking surfaceD.Roof capB.3¹⁄₄" x 10" (8.3 x 25.4 cm) vent through the wallC.18" (45.7 cm) to 24" (61.0 cm) above cooking surfaceD.Wall cap

A

B

D
C

A

B

C

D

3¹⁄₄" x 10" A.6" (15.2 cm) round vent or a (8.3 x 25.4 cm) vent thro ugh wall3¹⁄₄"