LOCATE AS FAR
FROM HOOD AS
POSSIBLE
FIG. 4
VERTICAL VENTING
7” ROUND
7.Remove the hood and start all four screws in the center of the narrow neck of the keynole slot marked on the cabinet bottom. See Figure 3.
8.Remove proper venting knockout. If 7” (17.8 cm) round vertical venting, entire top knockout including rectangular
portion must be removed The best performance from your hood, with most air taken from the kitchen and when the hood is most quiet, comes when you top vent with 7” round duct pipe as shown in Figure 4.
| FOR | RECTANGULAR |
| VENTING: | There | are | predrilled | ||||
| holes | on | hood | so | you | can | attach | damper | to | hood | with |
| small | sheet metal | screws | included. |
|
|
|
| |||
9. | Install | proper | ductwork. | For | round | vented | installations, | a | |||
| round | damper | should be placed in the ductwork | to prevent | |||||||
| air infiltration. |
|
|
|
|
|
|
|
| ||
10. | Lift | the | hood | into | position | simultaneously | feeding | the | |||
| electrical | wire | through | the | knockout. |
|
|
|
|
11.Tighten four mounting screws to secure hood to cabinet. Be sure the screw heads are in the narrow neck of the keyhole slot.
12.Complete electrical wiring in the junction box according
to the National Electrical Code and applicable local codes,
13 Replace junction box cover
14. Seal holes around ventilating pipe and wiring passing through ceiling or outside wall with caulking or insulation to prevent heat loss.
YRAIN CAP
‘ER
IF RAIN CAP HAS
A DAMPER, REMOVE
DAMPER BLADE
FROM HOOD.
FIG. 5
VERTICAL VENTING
~~‘x IO” RECTANGULAR
IF RAIN CAP HAS
A DAMPER, REMOVE
DAMPER BLADE
FROM HOOD.
FIG. 6
FOR | VENTLESS |
|
|
|
|
|
|
|
| |||
INSTALLATION |
|
|
|
|
|
|
|
| ||||
1. | To | convert | your | range | hood | to | ventless, | remove | the | |||
| discharge | grill shown | in | Figure | 7 | by pulling | with | fingers. | ||||
| Remove the metal back seal from behind the louver. |
| ||||||||||
2. | Replace | discharge | grill | and secure | with plastic | rivets | by | |||||
| pushing | with | thumb. |
|
|
|
|
|
|
|
| |
3. | Follow | instructions | under | “Vented | Installations” |
| for wiring | |||||
| and | mounting. | .Omit |
| ductwork | preparations. |
|
|
|
4.Install charcoal filter from ventless kit behind aluminum filter. (See Figure 8).
HORIZONTAL VENTING
rDlSCHARGE GRILL
FIG. 7