Complete Connection
1.Locate gas pressure regulator in the broiler.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
2.Check that the gas pressure regulator shutoff valve is in the
“ON” position.
Gas Pressure Regulator
Check Operation
Electronic Ignition System
Cooktop and oven burners use electronic ignitors in place of standing pilots. When a cooktop control knob is turned to the “LITE” position, the system creates a spark to light the burner. This sparking continues until the control knob is turned to the desired setting.
When the oven control is turned to the desired setting, a hot surface ignitor heats to a bright orange and ignites the gas. No sparking occurs. The glow bar remains on while the burner operates.
Check Operation of Cooktop Burners
1. If control panel and knobs were | OFF | |
removed earlier, reinstall knobs. | ||
|
Front View | Front | Side View |
| ||
Shutoff valve |
| “ON” Position |
3.Open the manual shutoff valve in the gas supply line. The valve is “open” when the handle is parallel to the gas pipe.
A
B
2. | Push in and turn each surface | LITE |
| unit control knob to “LITE” | |
|
| |
| position. The flame should light |
|
| within 4 seconds. | HI |
|
| |
3. | Turn control knob to “HI” |
|
| position after burner lights. |
|
4. | Check each cooktop burner for |
|
| proper flame. The small inner |
|
cone should have a very distinct blue flame ¹⁄₄" (6.4 mm) to ¹⁄₂" (13 mm) long. The outer cone is not as distinct as the inner cone.
LO
MED
outer cone
inner cone
A. Closed valve
B. Open valve
4.Test all connections by brushing on an approved noncorrosive
5.Close the broiler door.
6.Place burners, burner caps and grates on the cooktop.
WARNING
Electrical Shock Hazard
5.Turn the control knob quickly to the “LO” position after the burner lights. If the
flame goes out, turn the control knob to the “OFF” position.
6.Check each cooktop burner for proper low flame. The low flame should be a minimum, steady blue flame. The flame size should be ¹⁄₄" to ³⁄₈" (6.4 mm to 9.5 mm) high.
If the low flame needs adjusting:
1.Turn control knob to the “LO” setting and remove control knob.
2.Insert a small
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
A
as needed.
A. Valve stem
7.Plug into a grounded
3.Replace control knob.
10