GAS CONVERSIONS
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
NOTE: Gas conversions (from natural gas to LP gas or from LP gas to natural gas) must be done by a qualified person.
LP Gas Conversion
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Connect
Reconnect the
Failure to follow these instructions can result in death or serious burns to children and adults.
To Convert Gas Pressure Regulator
1.Ensure that the manual shutoff valve is in the closed position.
A
C
B
A. Shutoff valve in “open” position
A. Shutoff valve in “open” position
B. Gas supply line
C. To range
2.Unplug or disconnect power.
3.Open broiler door and remove broiler pan. The gas pressure regulator is located in the back right hand corner of the broiler compartment.
A
A. Gas pressure regulator
IMPORTANT: Do not remove the gas pressure regulator.
NOTE: Do not remove the spring beneath the cap.
4.Remove the cap from the gas pressure regulator using a flat- blade screwdriver.
5.Turn the cap over so that LP is visible.
A
A. Cap
6.Reinstall the cap.
To Convert Surface Burners
1.Remove burner grate, burner caps, and burners.
A
B
A. Burner cap
B. Burner
12