Dryer Dimensions
43½"
(110.5 cm)
| 22¼" |
*29¼" | (56.5 cm) |
(74.3 cm) | 29" |
| |
| (73.7 cm) |
*Most installations require a minimum 5" (12.7 cm) clearance behind the dryer for the exhaust vent with elbow. See “Venting Requirements.”
Installation spacing for recessed area or closet installation
The following spacing dimensions are recommended for this dryer. This dryer has been tested for spacing of 0" (0 cm) clearance on the sides and rear. Recommended spacing should be considered for the following reasons:
■Additional spacing should be considered for ease of installation and servicing.
■Additional clearances might be required for wall, door and floor moldings.
■Additional spacing should be considered on all sides of the dryer to reduce noise transfer.
■For closet installation, with a door, minimum ventilation openings in the top and bottom of the door are required. Louvered doors with equivalent ventilation openings are acceptable.
■Companion appliance spacing should also be considered.
■Additional spacing is required if you exhaust out the rear of the dryer to either the right or left side.
Mobile home installations require:
■Metal exhaust system hardware, which is available for purchase from your dealer.
■Mobile home Installation Kit Part Number 346764. See “Tools and Parts” section for information on ordering.
■Special provisions must be made in mobile homes to introduce outside air into the dryer. The opening (such as a nearby window) should be at least twice as large as the dryer exhaust opening.
Electrical Requirements
WARNING
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death, fire, or electrical shock.
■120 Volt, 60 Hz., AC only, 15- or
GROUNDING INSTRUCTIONS
|
|
|
| 14" max.* | 48 in.2 * | |
|
|
|
| (35.6cm) | ||
18"* |
|
|
|
|
| (310 cm2 ) |
|
|
|
|
|
| |
(45.7 cm) |
|
|
|
|
|
|
|
|
|
|
|
| 24 in.2 * |
|
|
|
|
|
| (155 cm2 ) |
1" | 29" | 1" | 1"* | 29¼" | 5" |
|
(2.5 cm) | (73.7 cm) | (2.5 cm) | (2.5 cm) (74.3 cm) (12.7 cm) | |||
| A |
|
| B |
|
|
3"* (7.6 cm)
3"* (7.6 cm)
C
■For a grounded, cord-connected dryer:
This dryer must be grounded. In the event of malfunction or breakdown, grounding will reduce the risk of electric shock by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment- grounding conductor and a grounding plug. The plug must be plugged into an appropriate outlet that is properly installed and grounded in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment- grounding conductor can result in a risk of electric shock.
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Mobile home - Additional installation requirements
This dryer is suitable for mobile home installations. The installation must conform to the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety, Title 24, HUD Part 280) or Standard
Check with a qualified electrician or service representative or personnel if you are in doubt as to whether the dryer is properly grounded. Do not modify the plug provided with the dryer: if it will not fit the outlet, have a proper outlet installed by a qualified electrician.