Base Grille Water Filtration System
Model P1WG2L/P2RFWG2 Capacity 200 Gallons (757 Liters)
Model P1WG2/P2RFWG2 Capacity 200 Gallons (757 Liters)
System tested and certified by NSF International against NSF/ANSI
Standard 42 for the reduction of Chlorine Taste and Odor, Particulate
Class I*; and against NSF/ANSI Standard 53 for the reduction of Lead,
Mercury, Benzene, Toxaphene, and
This system has been tested according to NSF/ANSI Standards 42 and 53 for the reduction of the substances listed below. The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system, as specified in NSF/ANSI Standards 42 and 53.
Substance Reduction | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Aesthetic Effects | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
Chlorine Taste/Odor | 50% reduction | 1.909 mg/L | 2.0 mg/L ± 10% | 0.05 mg/L | <0.05 mg/L | >97.4 | >97.4 |
Particulate Class I* | 85% reduction | 5166666 #/mL | At least 10,000 particles/mL | 4200 #/mL** | 1900 #/mL | >99.9 | >99.9 |
Contaminant | NSF Reduction | Average | Influent Challenge | Maximum | Average | Minimum % | Average % |
Reduction | Requirements | Influent | Concentration | Effluent | Effluent | Reduction | Reduction |
Lead: @ pH 6.5 | 0.010 mg/L | 143.33 ug/L | 0.15 mg/L ± 10% | 1.0 ug/L | 1.0 ug/L | >99.3 | >99.3 |
Lead: @ pH 8.5 | 0.010 mg/L | 150 ug/L | 0.15 mg/L ± 10% | 1.0 ug/L | 1.0 ug/L | >99.3 | 99.3 |
Mercury: @ pH 6.5 | 0.002 mg/L | 0.0058 mg/L | 0.006 mg/L ± 10% | 0.3 ug/L | 0.0002 mg/L | 94.8 | 96.4 |
Mercury: @ pH 8.5 | 0.002 mg/L | 0.00646 mg/L | 0.006 mg/L ± 10% | 0.8 ug/L | 0.0004 mg/L | 88.5 | 94.9 |
Benzene | 0.005 mg/L | 0.015 mg/L | 0.015 mg/L ± 10% | 0.5 ug/L | 0.0005 mg/L | >96.7 | >96.7 |
0.6 mg/L | 1.83333 mg/L | 1.8 mg/L ± 10% | 160 ug/L | 0.005 mg/L | 91.1 | 96.5 | |
Toxaphene | 0.003 mg/L | 0.016 mg/L | 0.015 mg/L ± 10% | 1 ug/L | 0.001 mg/L | >93.8 | >93.8 |
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 68°F to 71.6°F (20°C to 22°C). Rated service capacity = 200 gallons (757 liters).
■It is essential that operational, maintenance, and filter replacement requirements be carried out for the product to perform as advertised.
■Use replacement filter P2RFWG2, part #4396841.
2010 suggested retail price of $39.99 U.S.A./$54.95 Canada. Prices are subject to change without notice.
Model P1WG2L/P1WG2: Style 1 – When the filter indicator reads 10%, order a new filter. When the indicator reads 0%, it is recommended that you replace the filter.
Style 2 – When the filter indicator changes from green to yellow, order a new filter. When the indicator changes from yellow to red, it is recommended that you replace the filter.
■These contaminants are not necessarily in your water supply. While testing was performed under standard laboratory conditions, actual performance may vary.
■The product is for cold water use only.
■Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system.
■Refer to the “Warranty” section for the Manufacturer’s name, address and telephone number.
■Refer to the “Warranty” section for the Manufacturer’s limited warranty.
Style 3 – When the water filter status display changes from “GOOD” to “ORDER,” order a new filter. When the filter indicator reads “REPLACE,” it is recommended that you replace the filter.
Style 4 – Press FILTER to check the status of your water filter. If the filter indicator light is yellow, order a new filter. If the filter indicator light is red, it is recommended that you replace the filter.
Change the water filter cartridge every 6 months. If the water flow to the water dispenser or ice maker decreases noticeably before 6 months have passed, replace the water filter cartridge more often.
Application Guidelines/Water Supply Parameters
Water Supply | City or Well |
Water Pressure | 30 - 120 psi (207 - 827 kPa) |
Water Temperature | 33° - 100°F (0.6° - 37.8°C) |
Service Flow Rate | 0.5 gpm (1.9 Lpm) @ 60 psi |
*Class I particle size: >0.5 um to <1 um
**Test requirement is at least 100,000 particles/mL of AC Fine Test Dust. ® NSF is a registered trademark of NSF International.
16