Venting Installation
instructions
Continued
High Altitude Installation
Your
When installing this fireplace at an elevation above 2000 feet (in the USA), you may need to decrease the input rating by changing the existing burner orifice to a smaller size. Reduce input 4% for each 1000 feet above sea level. Check with your local gas company for proper orifice size identification.
When installing this fireplace at an elevation above 4500 feet (in Canada), check with local authorities.
Consult your local gas company to help determine the proper orifice for your location.
For assistance with any high altitude installation contact DESA Customer Service Department at
Parts lists for venting kits and components
DESA (5/8") Pipe & Vent Kits
Number Description
01492 Horizontal Square Termination Kit
Includes: 45° Elbow (Through 5" Wall), Wall Fire- stop, Horizontal Square Termination
01493 Basic Vertical Termination Kit
Includes: Vertical Termination, Adjustable Flash- ing, Storm Collar
01491 Horizontal Round Termination Kit
Includes: Round Termination, Wall Firestop, and 45° Elbow (Through 5" Wall)
01497 12" Section Coaxial Pipe - Galvanized (4)
01498 18" Section Coaxial Pipe - Galvanized (4)
01499 24" Section Coaxial Pipe - Galvanized (4)
01500 36" Section Coaxial Pipe - Galvanized (4)
01501 48" Section Coaxial Pipe - Galvanized (4)
01513 6" Section Coaxial Pipe - Galvanized (4)
01606 Adjustable
Galvanized (4)
F8030 Adjustable
Galvanized (6)
D1032 Adjustable
Galvanized (1)
DESA Elbows
Number Description
01502 45° Elbow - Galvanized (4)
01503 90° Elbow - Galvanized (4)
DESA Terminations
Number Description
01494 Vertical Round Termination - Galvanized (1)
01495 Horizontal Round Termination - Galvanized (1)
01496 Horizontal Square Termination - Galvanized (1)
01798 Vertical Round High Wind Termination (1)
01800 Horizontal Square High Wind Termination (1)
01801 14" Snorkel Termination - Galvanized (1)
01802 36" Snorkel Termination - Galvanized (1)
DESA Venting Accessories
Number Description
01504 Firestop Plate (4)
01505 Adjustable Roof Flashing 0 to 8/12 - Galvanized (6) 01506 Steep Pitch Flashing 9/12 to 12/12 - Galvanized (6) 01507 Storm Collar - Galvanized (4)
01508 Wall Strap (4)
01514 Combustible Siding Standoff - Galvanized (1)
01607 Wall Firestop - Galvanized (4)
Fireplace Installation
CHECK GAS TYPE
Use proper gas type for the fireplace unit you are installing. If you have conflicting gas types, do not install fireplace. See retailer where you purchased the fireplace for proper fireplace according to your gas type.
Installing optional blower accessories
NOTICE: If installing blower in an existing fireplace with gas connections, shut off gas supply and disconnect heater from gas supply. Contact a qualified service person to do this.
WARNING: If there is a duplex electrical outlet in- stalled in the right side of the bottom of the fireplace base area, be sure that the electrical power to the outlet is turned off before proceeding with blower installation. Failure to do this may result in serious injury.
Model BK Installation
Follow all instructions provided in the blower accessory kit.
1.Attach the power cord to the blower motor by firmly pushing the two female terminals at the end of the power cord onto the two spade terminals on the blower motor (see Figure 25, page 15).
2.Attach green ground wire from power cord to blower housing using screw provided (see Figure 25, page 15). Tighten screws securely.
14 | www.desatech.com |