3-Wire Cable from Power Supply to 4-Wire Cable from Cooktop

IMPORTANT: Use the 3-wire cable from power supply where local codes permit connecting the frame-ground conductor to the neutral (white) junction box wire:

A

E

B

F

G

H

C

I

D

A. 3-wire cable from power

F. White wire (from power

supply

supply)

B. Red wires

G. UL listed wire connector

C. White and green or bare

H. Black wires

ground wires (from cooktop)

I. UL listed or CSA approved

D. 4-wire cable from cooktop

conduit connector

E. Junction box

 

1.Disconnect power.

2.Remove junction box cover if present.

3.Connect the flexible, cable conduit from the cooktop to the junction box using UL listed or CSA approved conduit connector.

4.Tighten screws on conduit connector, if present.

5.Connect the two black wires together using the UL listed wire connectors.

6.Connect the two red wires together using the UL listed wire connectors.

7.Connect the green or bare and white cooktop cable wires to the white (neutral) wire in the junction box using the UL listed wire connectors.

8.Install junction box cover.

9.Reconnect power.

4-Wire Cable from Power Supply to 3-Wire Cable from Cooktop

IMPORTANT: Use the 4-wire cable from power supply where local codes do not permit connecting the frame-ground conductor to the neutral (white) junction box wire:

A

B

E

F

 

 

G

C

H

 

D

I

 

A. 4-wire cable from power

F. White wire (from power supply)

supply

G. UL listed wire connector

B. Red wires

H. Black wires

C. Green or bare ground wire

I. UL listed or CSA approved

(from cooktop)

conduit connector

D. 3-wire cable from cooktop

 

E. Junction box

 

1.Disconnect power

2.Remove junction box cover if present.

3.Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or CSA approved conduit connector.

4.Tighten screws on conduit connector, if present.

5.Connect the two black wires together using the UL listed wire connectors.

6.Connect the two red wires together using the UL listed wire connectors.

7.Connect the green or bare ground wire from the cooktop cable to the green or bare ground wire (in the junction box) using the UL listed wire connectors.

8.Put a UL listed wire connector on the end of the white wire.

NOTE: Do not connect the bare ground wire to the neutral (white) wire in the junction box.

9.Install junction box cover.

10.Reconnect power.

7

Page 7
Image 7
Whirlpool W10346695A installation instructions Wire Cable from Power Supply to 3-Wire Cable from Cooktop