GAS CONVERSIONS
Gas conversions from Natural gas to LP gas or from LP gas to Natural gas must be done by a qualified installer.
LP Gas Conversion
WARNING
Explosion Hazard
Use a new CSA International approved gas supply line.
Install a
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 14" (36 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
WARNING
Tip Over Hazard
A child or adult can tip the range and be killed.
Install
Slide range back so rear range foot is engaged in the slot of the
Do not operate range without
Failure to follow these instructions can result in death or serious burns to children and adults.
1.Turn the manual shutoff valve to the closed position.
B
A
C
A. To rangeB. Manual shutoff valve “closed” position
C. Gas supply line2.Unplug range or disconnect power.
To Convert Gas Pressure Regulator (Natural Gas to LP Gas)
1.Remove storage drawer, warming drawer or premium storage drawer. See the “Storage Drawer” or “Warming Drawer or Premium Storage Drawer” section.
2.Locate gas pressure regulator at rear of storage or warming drawer compartment.
NOTE: On models with a warming drawer, an access cover must be removed to access the gas pressure regulator.
A
IMPORTANT: Do not remove the gas pressure regulator.
14