WHITE-RODGERS

TYPE 1131

HOT WATER CONTROL

S.P.D.T. Well-Immersion

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

Type 1131 controls are designed for use on hot water heating installations. They have single-pole, double-throw switch action, offering open-on-rise terminals as well as close-on-rise terminals. These controls may be used as a high limit, low limit, circulator, or combination low limit- circulator control.

Models are available with either horizontal or vertical well, and with either fixed or adjustable differential. Some of these models also have excess capillary stored within the enclosure, permitting them to be used with wells having either a standard or extended shank.

Another model, ideal for replacement purposes, has both a slotted case and excess capillary stored within the enclosure. This control can be used with either a standard or extended shank well, on either horizontal or vertical well installations.

THIS CONTROL MUST BE INSTALLED BY A QUALIFIED INSTALLER.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

This control has been accurately calibrated at the factory. Any attempt to calibrate this control will void the White- Rodgers warranty.

PRECAUTIONS

CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

WARNING

Do not use on circuits exceeding specified voltages. Higher voltages will damage control and could cause shock or fire hazard.

Convertible controls have a Knockout Plate on back of case (secured by Hex Nut on Horizontal models, and by Knockout Plug on Vertical models). To convert from Horizontal to Vertical:

1.Remove control cover. Then remove bottom knockout.

2.Remove Hex Nut (inside control) from Well Mounting Stem. (To loosen, hold Hex Nut inside while turning Hex Nut on back of control counterclockwise.)

CONVERTIBLE CONTROLS

3.Pull Well Mounting Stem away from case and remove Knockout Plate.

4.Swing capillary down through slot into bottom knock- out.

5.Secure Knockout Plate to back of case by using Knockout Plug provided in envelope.

6.Insert Well Mounting Stem into bottom knockout and tighten Hex Nut (inside control) securely.

WHITE-RODGERS DIVISION

 

EMERSON ELECTRIC CO.

 

9797 REAVIS RD., ST. LOUIS, MO. 63123

 

(314) 577-1300, FAX (314) 577-1517

Printed in U.S.A.

 

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

 

(905) 475-4653, FAX (905) 475-4625

 

PART NO. 37-2071B

Replaces 37-2071 & 37-9195 9548

Page 1
Image 1
White Rodgers 1131 installation instructions Type, HOT Water Control, Description, Precautions, Convertible Controls

1131 specifications

The White Rodgers 1131 is a versatile and reliable thermostat designed for residential heating and cooling systems. Renowned for its user-friendly interface and advanced features, it caters to homeowners looking for comfort and energy efficiency. This model stands out due to its robust construction and ease of use, making it an excellent choice for both modern and traditional HVAC systems.

One of the primary features of the White Rodgers 1131 is its digital display, which provides clear visibility of the current room temperature and set points. This display simplifies temperature adjustments and allows users to monitor their system easily. The thermostat is equipped with a simple programming interface that enables users to set up heating and cooling schedules according to their lifestyle, effectively optimizing energy consumption.

The White Rodgers 1131 employs advanced temperature control technologies, delivering precise temperature regulation that enhances overall comfort. This model supports dual fuel systems, making it compatible with a variety of heating sources, including heat pumps, gas, and oil furnaces. This flexibility ensures it can effectively manage heating and cooling demands in diverse climates, maintaining a comfortable indoor environment year-round.

Another notable characteristic is its energy-saving capabilities. The thermostat provides features that facilitate energy-efficient operation, such as adjustable setback settings. Homeowners can program lower temperatures during unoccupied hours and return to comfortable levels before their arrival, significantly reducing energy bills without sacrificing comfort.

Moreover, the White Rodgers 1131 integrates advanced features like an intuitive keypad and consistent performance. The replaceable battery ensures continued operation even during power outages, providing peace of mind during extreme weather conditions. This model is designed for easy installation, compatible with most standard electrical wiring.

In summary, the White Rodgers 1131 thermostat is an excellent choice for homeowners seeking a reliable and efficient climate control solution. Its combination of user-friendly programming, dual fuel compatibility, and energy-saving features positions it as a top pick in the thermostat market, ensuring optimal comfort while reducing energy costs. With its robust design and adaptability, the White Rodgers 1131 is engineered to meet diverse residential heating and cooling needs for years to come.