1E30(W)/1F30(W)

WHITE-RODGERS

Non-Anticipated

Millivolt Room Thermostat

 

 

INSTALLATION INSTRUCTIONS

 

 

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

DESCRIPTION

These low voltage thermostats are specially designed for use on self-generating systems. They are non-antici- pated, enabling them to be used on self-generated sys- tems having pilot generator outputs from 250 to 750 millivolts.

1F30

1E30

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

CONTENTS

 

Description

1

Precautions

1

Specifications

2

Installation

2

Select Thermostat Location

 

Route Wires to Location

 

Attach Thermostat to Wall

 

Operation & Maintenance

3

Calibrating Thermometer

 

Calibrating Thermostat

 

PRECAUTIONS

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will burn out heat anticipator and could cause personal injury and/or property damage.

!WARNING

Do not use on circuits exceeding 750 millivolts. Higher voltage will damage control and could cause shock or fire hazard.

ATTENTION!

This product contains mercury. There will not be any exposure to mercury under normal conditions of use. This product may replace a unit which contains mercury. Do not open mercury cells. If a cell becomes damaged, do not touch any spilled mercury. Wearing non-absorbent gloves, take up the spilled mercury with sand or other absorbent material and place into a container which can be sealed. If a cell becomes damaged, the unit should be discarded. Mercury must not be discarded in household trash. When this unit or the unit it is replacing is to be discarded, place in a suitable container and return to us at WHITE-RODGERS.

WHITE-RODGERS DIVISION

PART NO. 37-5583A

EMERSON ELECTRIC CO.

Replaces 37-9587C

9797 REAVIS RD., ST. LOUIS, MO. 63123

 

(314) 577-1300, Fax (314) 577-1517

9531

Printed in U.S.A.

9999 HWY. 48, MARKHAM, ONT. L3P 3J3

 

(905) 475-4653, FAX (905) 475-4625

 

R

Page 1
Image 1
White Rodgers 1E30 (W), 1F30(W), 1E30(W), 1F30 (W) installation instructions Description, Precautions, Contents

1E30 (W), 1E30(W), 1F30(W), 1F30 (W) specifications

White Rodgers is renowned for its innovative thermostats and control systems, offering a range of products designed to enhance energy efficiency and comfort in residential and commercial spaces. The models 1F30(W), 1F30(W), 1E30(W), and 1E30(W) exemplify their commitment to quality and advanced technology.

The White Rodgers 1F30 series is a programmable thermostat that benefits homeowners with its user-friendly interface and customizable features. One of its main highlights is its ability to program settings for different times of the day and days of the week, allowing users to adjust temperatures based on their specific schedules. This helps optimize energy consumption, reducing unnecessary heating or cooling when it’s not needed.

Key features of the 1F30 models include a large, easy-to-read display which simplifies temperature adjustments and settings. The models boast intuitive controls that make programming a straightforward process even for users who may not be technologically savvy. Enhanced control means better comfort, providing consistent temperatures throughout the home.

The 1E30 series shares many characteristics with the 1F30 models but is typically aimed at economical and efficient heating systems. With similar programming functionalities, it offers flexibility and efficiency without sacrificing performance. The 1E30 series is particularly noted for its compatibility with various HVAC systems, making it a versatile option for homeowners with diverse heating and cooling needs.

Both the 1F30 and 1E30 series utilize advanced technology such as digital temperature sensing, which ensures accurate readings and reduces fluctuations, creating a more stable indoor environment. Additionally, features like auto-changeover and energy-saving programs help users maintain their desired comfort levels while minimizing energy costs.

In terms of installation, White Rodgers thermostats are designed to be user-friendly, with straightforward wiring and a simple setup process. This means that many homeowners can install the thermostat themselves, saving time and installation costs.

Overall, the White Rodgers 1F30 and 1E30 series bring together ease of use, innovative technology, and energy efficiency. These thermostats stand out for their ability to provide comfort while being mindful of energy consumption. With their modern features, they effectively cater to the needs of today's homeowners who value efficiency, reliability, and user-centric designs. In an era where smart home technology is becoming increasingly important, White Rodgers continues to lead by providing solutions that are not just functional but also seamlessly integrate into daily life.