White Rodgers 1F58-72 installation instructions Installation Instructions, Description

Models: 1F58-72

1 6
Download 6 pages 40.24 Kb
Page 1
Image 1
1F58-72

1F58-72

WHITE-RODGERSLow Voltage Multi-Stage Heat PumpThermostat

INSTALLATION INSTRUCTIONS

Operator: Save these instructions for future use!

FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL INJURY AND/OR PROPERTY DAMAGE.

This thermostat and subbase combination is designed to control a heat pump system where automatic changeover is not required. The reversing valve may be energized when the SYSTEM switch is moved to the HEAT or COOL position.

The subbase is equipped with EMER HEAT, AUX HEAT, and CHECK operation indicator lights.

CHECK

LIGHT

AUX

HEAT

EMER

HEAT

DESCRIPTION

 

 

 

SYSTEM

EMER.

FAN

 

 

OFF HEAT

ON

COOL

 

AUTO

 

 

 

 

 

 

 

70

80

90

60

 

 

 

90

80

50

 

 

 

70

 

 

 

 

 

 

60

 

 

 

50

If in doubt about whether your wiring is millivolt, line, or low voltage, have it inspected by a qualified heating and air conditioning contractor, electrician, or someone familiar with basic electricity and wiring.

Do not exceed the specification ratings.

All wiring must conform to local and national electrical codes and ordinances.

This control is a precision instrument, and should be handled carefully. Rough handling or distorting compo- nents could cause the control to malfunction.

PRECAUTIONS

!CAUTION

To prevent electrical shock and/or equipment damage, disconnect electric power to system, at main fuse or circuit breaker box, until installation is complete.

Do not short out terminals on gas valve or primary control to test. Short or incorrect wiring will burn out heat anticipator and could cause personal injury and/or property damage.

!WARNING

Do not use on circuits exceeding 30 volts. Higher voltage will damage control and could cause shock or fire hazard.

ELECTRICAL DATA

Switch Rating:

24 VAC

Stage 1 heat – 0 to 1.2 amp Stage 2 heat – 0.15 to 1.2 amp Cooling – 0 to 1.5 amp

Switch Action:

Stage 1 heat & cool – SPDT

Stage 2 heat – SPST (sealed mercury contacts)

Anticipator Rating:

Stage 1 heat – 24 VAC, fixed

Stage 2 heat – 0.15 to 1.2 amp, adjustable Cooling – 24 VAC, fixed

SPECIFICATIONS

Circuit: Manual Changeover – Reversing valve may be energized when the SYSTEM switch is switched either the HEAT or COOL position on the subbase (see wiring diagram).

THERMAL DATA

Temperature Range: 50°F to 90°F (10°C to 32°C)

Rated Differential: Stage 1 heat – 1.5°F Stage 2 heat – 1°F Cooling – 1.5°F

DIMENSIONS (INCLUDING SUBBASE):

Height 314 ”, width 534”, depth 218

WHITE-RODGERS DIVISION

 

PART NO. 37-4046F

EMERSON ELECTRIC CO.

Printed in U.S.A.

9797 REAVIS ROAD

Replaces 37-4046E

ST. LOUIS, MISSOURI 63123-5398

 

9414

Page 1
Image 1
White Rodgers 1F58-72 installation instructions Installation Instructions, Operator Save these instructions for future use