Configuration Menu

Step

Press Button(s)

Displayed (Factory Default)

Press

or

to select:

COMMENTS

 

 

 

 

 

 

 

1

PRGM

HOLD

 

0 to 8 hrs (in

 

Select temporary Hold time

 

and RUN

(0:00)

15 minute increments)

 

2

HOLD*

 

 

SL

 

Select FA or SL (Fast or Slow) heating cycle rate

 

 

(FA)

 

 

 

 

 

 

 

 

 

 

 

3

HOLD*

d-L

 

OFF

 

Select display backlight OFF or ON

 

 

(ON)

 

 

 

 

 

 

 

 

 

 

 

4

HOLD*

LOC

 

ON

 

Select compressor lockout OFF or ON

 

 

(OFF)

 

 

 

 

 

 

 

 

 

 

 

5

HOLD*

0 HI

 

4 LO to

 

Select temperature display adjustment higher or lower

 

 

(0)

 

4 HI

 

 

6

HOLD*

(F)

 

C

 

Select temperature display to F or C

 

 

 

 

 

 

 

7

RUN

 

 

 

 

Returns to normal operation

 

 

 

 

 

 

 

*Press HOLD to advance to next item or TIME to move backwards to previous item

5Select Temperature Display Adjustment 4 LO to 4 HI - Allows you to adjust the room temperature display 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat.

6)Select F° or C° Readout - Changes the display readout to Centigrade or Fahrenheit as required.

OPERATING FEATURES

Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.

SIMULTANEOUS HEATING/COOLING PROGRAM STORAGE — When programming, you can enter both your heating and cooling programs at the same time. There is no need to reprogram the thermostat at the beginning of each season.

TEMPERATURE OVERRIDE — Press or until the display shows the temperature you want. The thermostat will override current programming and keep the room temperature at the selected temperature until the next program period begins. Then the thermostat will automati- cally revert to the program.

HOLD TEMPERATURE — The thermostat can hold any temperature within its range for an indefinite period without reverting to the programmed temperature. Momentarily

press HOLD button. HOLD will be displayed. Then choose

the desired temperature by pressing or . The thermostat will hold the room temperature at the selected setting until you press RUN button to start program opera- tion again.

SAMPLE

Heating/Cooling Schedule Plan (Factory Program)

 

Start

 

Period

Time

Temperature

1ST HEAT

6:00 AM

70˚F

 

 

 

2ND HEAT

8:00 AM

62˚F

 

 

 

3RD HEAT

5:00 PM

70˚F

 

 

 

4TH HEAT

10:00 PM

62˚F

 

 

 

1ST COOL

6:00 AM

78˚F

 

 

 

2ND COOL

8:00 AM

85˚F

 

 

 

3RD COOL

5:00 PM

78˚F

 

 

 

4TH COOL

10:00 PM

82˚F

 

 

 

CONFIGURATION MENU — Allows you to customize certain thermostat options.

PROGRAMMING YOUR THERMOSTAT

This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.

• When heating (cooling) your building, program the temperatures to be cooler (warmer) when the building is vacant or during periods of low activity.

During early morning hours, the need for cooling is usually minimal.

Planning Your Program

Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN button to begin running the factory preset program.

If you want to change the preprogrammed times and tempera- tures, follow these steps.

Determine the time periods and temperatures for your program. You must program four time periods. However, you may use the same heating and cooling temperatures for consecutive time periods.

Use the following table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs.

Heating/Cooling Schedule Plan

 

Start

 

Period

Time

Temperature

1ST HEAT

 

 

 

 

 

2ND HEAT

 

 

 

 

 

3RD HEAT

 

 

 

 

 

4TH HEAT

 

 

 

 

 

1ST COOL

 

 

 

 

 

2ND COOL

 

 

 

 

 

3RD COOL

 

 

 

 

 

4TH COOL

 

 

 

 

 

5

Page 5
Image 5
White Rodgers 1F80-224 specifications Operating Features, Programming Your Thermostat, Planning Your Program