4)Select Energy Management Recovery OFF or ON - Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building

temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint.

Example: You select EMR and have your heating pro- grammed to 65° at night and 70° at 7 AM. If the building temperature is 65° the difference between 65° and 70° is 5°.

Allowing 5 minutes per degree the thermostat setpoint will change to 70° at 6:35 AM. Cooling allows more time per degree because it takes longer to reach temperature.

5)Select Compressor Lockout LOC OFF or ON - Selecting LOC ON will cause the thermostat to wait 5 minutes before turning on the compressor if the heating and cooling system loses power. It will also wait 5 minutes minimum between cooling cycles. This is intended to help protect the compres- sor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the feature is already present in their system. When the compressor time delay occurs it will flash the (snowflake icon) for about five minutes then turn on the compressor.

6)Select Temperature Display Adjustment 4 LO to 4 HI - Allows you to adjust the room temperature display 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat.

7)Select F° or C° Readout - Changes the display readout to Celsius or Fahrenheit as required.

OPERATING FEATURES

Now that you are familiar with the thermostat buttons and display, read the following information to learn about the many features of the thermostat.

SIMULTANEOUS HEATING/COOLING PROGRAM STORAGE — When programming, you can enter both your heating and cooling programs at the same time. There is no need to reprogram the thermostat at the beginning of each season.

TEMPERATURE OVERRIDE — Press or until the display shows the temperature you want. The thermostat will override current programming and keep the room temperature at the selected temperature until the next program period begins. Then the thermostat will automati- cally revert to the program.

HOLD TEMPERATURE — The thermostat can hold any temperature within its range for an indefinite period without reverting to the programmed temperature. Momentarily

SAMPLE

Heating/Cooling Schedule Plan (Factory Program)

 

 

 

WEEKDAY (5 DAY)

SATURDAY (1 DAY)

SUNDAY (1 DAY)

 

Period

Start

 

Start

 

Start

 

 

Time

Temperature

Time

Temperature

Time

Temperature

 

 

1ST

6:00 AM

70˚F

6:00 AM

70˚F

6:00 AM

70˚F

HEAT

 

 

 

 

 

 

 

 

 

2ND

8:00 AM

62˚F

8:00 AM

62˚F

8:00 AM

62˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

5:00 PM

70˚F

5:00 PM

70˚F

5:00 PM

70˚F

 

 

 

 

 

 

 

 

 

 

 

4TH

10:00 PM

62˚F

10:00 PM

62˚F

10:00 PM

62˚F

 

 

 

 

 

 

 

 

 

 

 

1ST

6:00 AM

78˚F

6:00 AM

78˚F

6:00 AM

78˚F

COOL

 

 

 

 

 

 

 

 

 

2ND

8:00 AM

85˚F

8:00 AM

85˚F

8:00 AM

85˚F

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

5:00 PM

78˚F

5:00 PM

78˚F

5:00 PM

78˚F

 

 

 

 

 

 

 

 

 

 

 

4TH

10:00 PM

82˚F

10:00 PM

82˚F

10:00 PM

82˚F

 

 

 

 

 

 

 

 

 

press HOLD button. HOLD will be displayed. Then choose

the desired temperature by pressing or . The thermostat will hold the room temperature at the selected setting until you press RUN button to start program opera- tion again.

CONFIGURATION MENU — Allows you to customize certain thermostat options.

PROGRAMMING YOUR THERMOSTAT

This section will help you plan your thermostat’s program to meet your needs. For maximum comfort and efficiency, keep the following guidelines in mind when planning your program.

When heating (cooling) your building, program the tem- peratures to be cooler (warmer) when the building is vacant or during periods of low activity.

During early morning hours, the need for cooling is usually minimal.

Planning Your Program

Look at the factory preprogrammed times and temperatures shown in the sample schedule. If this program will suit your needs, simply press the RUN button to begin running the factory preset program.

If you want to change the preprogrammed times and tempera- tures, follow these steps.

Determine the time periods and temperatures for your weekday and weekend programs. You must program four periods for both the weekday and weekend program. However, you may use the same heating and cooling temperatures for consecutive time periods. You can choose start times, heating temperatures, and cooling temperatures independently for both weekday and weekend programs (for example, you may select 5:00 AM and 70° as the weekday 1st period heating start time and tempera- ture, and also choose 7:00 AM and 76° as the weekday 1st period cooling start time and temperature).

Use the following table to plan your program time periods and the temperatures you want during each period. Fill in the complete table to have a record of your programs.

Entering Your Program

Follow these steps to enter the heating and cooling programs you have selected.

Set Current Time and Day

1. Press TIME button once. The display will show the hour only.

 

 

 

EXAMPLE:

 

PM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heating/Cooling Schedule Plan

 

 

 

 

 

 

WEEKDAY (5 DAY)

SATURDAY (1 DAY)

SUNDAY (1 DAY)

 

Period

 

Start

 

 

Start

 

 

Start

 

 

 

Time

Temperature

Time

Temperature

Time

Temperature

 

 

1ST

 

 

 

 

 

 

 

 

 

HEAT

 

 

 

 

 

 

 

 

 

 

 

 

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4TH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1ST

 

 

 

 

 

 

 

 

 

COOL

 

 

 

 

 

 

 

 

 

 

 

 

2ND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3RD

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4TH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

Page 5
Image 5
White Rodgers 1F80-241 Operating Features, Programming Your Thermostat, Planning Your Program, Entering Your Program

1F80-241 specifications

The White Rodgers 1F80-241 is a sophisticated programmable thermostat that highlights the intersection of functionality, efficiency, and user-friendly design. With its sleek appearance and advanced technology, the 1F80-241 is tailored to meet the needs of homeowners who seek control over their indoor climate.

One of the standout features of the 1F80-241 is its seven-day programmable schedule, allowing users to customize heating and cooling settings for each day of the week. This flexibility enables homeowners to optimize energy consumption by aligning the thermostat's operation with their daily routines. The ability to set distinct programs for weekends versus weekdays makes it particularly appealing for families with varying schedules.

The thermostat is equipped with a large, easy-to-read LCD display that shows the current and desired temperatures, making it simple to operate. The intuitive interface includes straightforward buttons that facilitate effortless adjustments. Additionally, the backlit display enhances visibility in low-light conditions, ensuring users can make changes at any time of day or night.

Energy efficiency is a key focus of the 1F80-241, as it features advanced algorithms that learn from user behavior and environmental factors. This allows the thermostat to make automatic adjustments, ultimately helping to reduce energy bills while maintaining a comfortable living space. The Smart Recovery feature preheats or precools the home to reach the desired temperature by the scheduled time, further increasing efficiency.

Another important characteristic of the White Rodgers 1F80-241 is its compatibility with a variety of HVAC systems, including gas, oil, and electric furnaces, allowing for versatile installation options. It is designed to work seamlessly with both conventional and heat pump systems, making it a highly adaptable choice for diverse home environments.

Additional features include a built-in filter change reminder that alerts homeowners when it’s time to replace or clean their HVAC filters, encouraging regular maintenance and promoting optimal system performance. Furthermore, the 1F80-241 incorporates a temporary hold feature that lets users override programmed settings for special occasions without altering the overall schedule.

In summary, the White Rodgers 1F80-241 is a highly efficient and user-centric programmable thermostat, boasting a wealth of features designed to enhance comfort while promoting energy savings. Its intuitive interface, programmable scheduling, and compatibility with multiple heating and cooling systems make it an excellent choice for any modern home.