INSTALLER/CONFIGURATION MENU

4 & 5) Select Cycle Rate Selection - The factory default setting is (FA, CR) for all modes (Heat Pump, Heat Pump Aux, Heat and Cool, Single Stage Heat and Single Stage Cool). To change to slow cycling (SL, CR), press the

and keys to toggle between FA & SL.

The cycle rate differentials for different settings are:

MODE

Fast

Slow

 

FA

SL

Heat Pump

1.2°F

1.7°F

HP Aux

0.8°F

1.2°F

SS Heat

0.8°F

1.2°F

SS Cool

1.2°F

1.7°F

6)Select Compressor Lockout CL OFF or ON - Selecting CL On will cause the thermostat to wait 5 minutes between cooling cycles. This is intended to help protect the compressor from short cycling. Some newer compressors already have a time delay built in and do not require this feature. Your compressor manufacturer can tell you if the lockout feature is already present in their system. When the thermostat compressor time delay occurs, it will flash the setpoint for up to five minutes.

7)Select Backlight Display - The display backlight improves display contrast in low lighting conditions. When the “C” terminal is connected, selecting backlight CdL On will keep the light on continuously. Select backlight OFF will turn the light on momentarily when any key is pressed. When the “C” terminal is not connected, regardless of the backlight selection, the light will be on momentarily when any key is pressed.

8)Select Temperature Display Adjustment 4 LO to 4 HI - Allows you to adjust the room temperature display up to 4° higher or lower. Your thermostat was accurately calibrated at the factory but you have the option to change the display temperature to match your previous thermostat. The current or adjusted room temperature will be displayed on the display.

9)Select °F or °C Readout - Changes the display readout to Celsius or Fahrenheit as required.

10)Select Fast Second Stage ON or OFF - (Heat Pump Only) In the RUN mode, with the Fast Heat feature enabled (FH Heat On), if the temperature is manually raised by 3°F (2°C)

or more above the actual temperature using the , the second stage will energize immediately. With FH OFF, the thermostat will determine the optimum time (approximately 0 to 30 minutes) to use Auxiliary/Second stage heat in addition to the Heat Pump.

11)Select Filter Replacement Reminder and Set Run Time Select the “Change Filter” reminder On or OFF. If selected On, press RUN/HOLD to select the time period from 25 to 1975 hours in 25 hour increments. In a typical application, 200 hours (default) of run time is approximately 30 days. After the selected time of blower operation, the thermostat will display “Change Filter” as a reminder to change or clean your air filter. When “Change Filter” is displayed, press the RUN/HOLD button to clear the display and restart the time to the next filter change. A selection of OFF will cancel this feature.

12)Select RUN/HOLD - Exit Menu.

OPERATION

CHECK THERMOSTAT OPERATION

If at any time during testing your system does not operate properly, contact a qualified service person.

Turn on power to the system.

Fan Operation

If your system does not have a G terminal connection, skip to Heating System.

1.Move fan switch to ON position. The blower should begin to operate.

2.Move fan switch to AUTO position. The blower should stop immediately.

Heating System

1.Move SYSTEM switch to HEAT position. If the auxiliary heating system has a standing pilot, be sure to light it.

2.Press to adjust thermostat setting to 1° above room temperature. The Heat Pump system should begin to operate. However, if the setpoint temperature is flashing, the compressor lockout feature is operating (see Configuration menu, item 6).

3.Adjust temperature setting to 4o above room temperature. The auxiliary heat system should begin to operate and the Flame icon will be flashing.

4.Press to adjust temperature setting below room temperature. The heating system should stop operating.

Emergency System

EMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the thermostat. EMER is typically used when compressor operation is not desired, or you prefer back-up heat only.

1.Move SYSTEM switch to EMER position, EMER will flash on the display.

2.Press to adjust the thermostat above room temperature. The Aux heating system will begin to operate. The Flame icon () will display flashing to indicate that the Aux system is operating.

3.Press to adjust the thermostat below room temperature. The Aux heating system should stop operating.

Cooling System

!CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50oF, DO NOT operate the cooling system.

1.Move SYSTEM switch to COOL position.

2.Press to adjust thermostat setting below room temperature. The blower should come on immediately on high speed, followed by cold air circulation.

3.Press to adjust temperature setting above room temperature. The cooling system should stop operating.

6

Page 6
Image 6
White Rodgers 1F82-0261 specifications Check Thermostat Operation

1F82-0261 specifications

The White Rodgers 1F82-0261 is a highly versatile and efficient programmable thermostat designed for residential applications. This device caters to homeowners who seek to optimize their heating and cooling systems while maintaining comfort and energy savings. Aimed at providing user-friendly functionality with advanced technology, it embodies a perfect blend of comfort and control.

One of the standout features of the 1F82-0261 is its easy-to-read, backlit display. This clear interface ensures that users can effortlessly read the current temperature at a glance, even in low-light conditions. The thermostat offers four programmable periods per day, allowing for extensive customization of heating and cooling schedules. Users can set different temperatures for mornings, days, evenings, and nights, accommodating varied household lifestyles and ensuring energy efficiency.

The device operates on a straightforward menu-driven programming system which simplifies the setup process. Users can easily navigate through options to create personalized schedules, making it simpler than ever to tailor climate control to individual preferences. Furthermore, the memory backup system protects user settings in case of a power outage, ensuring that your comfort settings remain intact.

Another notable characteristic is the compatibility of the 1F82-0261 with various heating and cooling systems. This thermostat works well with single-stage heating, heating only, cooling only systems as well as multi-stage systems, making it a flexible choice for diverse home setups.

The energy-saving features integrated into the 1F82-0261 help homeowners to manage their utility costs effectively. A key feature is the Energy Star designation, which indicates that the thermostat meets stringent energy efficiency guidelines. Additionally, the thermostat’s built-in reminders for filter changes contribute to maintaining system efficiency while prolonging the life of HVAC equipment.

In terms of installation, the White Rodgers 1F82-0261 is designed for ease of use. It includes a universal mounting plate for compatibility with various existing systems, and the installation process is straightforward, appealing to both novice DIYers and professionals.

In summary, the White Rodgers 1F82-0261 embodies modern technology with its user-friendly interface, energy-saving capabilities, and broad compatibility. It is a sought-after solution for homeowners looking to enhance comfort while making efficient use of their heating and cooling systems. This thermostat not only promises ease of use but also aims to deliver significant savings on energy bills, making it an intelligent choice for any household.