TROUBLESHOOTING

Reset Operation

If a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the thermostat by

pressing the , and PRGM buttons simultaneously. If

the thermostat has power, has been reset and still does not function correctly contact your heating/cooling service person or place of purchase.

Symptom

Possible Cause

Corrective Action

 

 

 

No Heat/No Cool/No Fan

1. Blown fuse or tripped circuit breaker.

Replace fuse or reset breaker.

(common problems)

2. Furnace power switch to OFF.

Turn switch to ON.

 

3. Furnace blower compartment door or

Replace door panel in proper position to engage safety

 

panel loose or not properly installed.

interlock or door switch.

 

 

 

No Heat

1. System Switch not set to Heat.

Set System Switch to Heat and raise setpoint above room

 

 

temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system

 

 

3. Heating System requires service or

Diagnostic: Set System Switch to Heat and raise the

 

thermostat requires replacement.

setpoint above room temperature. Within a five minutes

 

 

the thermostat should make a soft slick sound. This sound

 

 

usually indicates the thermostat is operating properly. If

 

 

the thermostat does not click, try the reset operation listed

 

 

above. If the thermostat does not click after being reset

 

 

contact your heating and cooling service person or place of

 

 

purchase for a replacement. If the thermostat clicks, con-

 

 

tact the furnace manufacturer or a service person to verify

 

 

the heating system is operating correctly.

 

 

 

No Cool

1. System Switch not set to Cool.

Set System Switch to Cool and lower setpoint below room

 

 

temperature.

 

2. Loose connection to thermostat or

Verify thermostat and system wires are securely attached.

 

system.

Same procedures as diagnostic for No Heat condition

 

3. Cooling System requires service or

except set the thermostat to Cool and lower the setpoint

 

thermostat requires replacement

below the room temperature. There may be up to a five

 

 

minute delay before the thermostat clicks in Cooling if the

 

 

compressor lock-out option is selected in the configuration

 

 

menu (Item 6).

 

 

 

Heat, Cool or Fan Runs

1. Possible short in wiring.

Check each wire connection to verify they are not shorted

Constantly

2. Possible short in thermostat.

or touching together. No bare wire should stick out from

 

3. Possible short in Heat/Cool/Fan

under terminal screws. Try resetting the thermostat as

 

system.

described below. If the condition persists, the manufacturer

 

4. Fan Switch set to Fan On.

of your system or service person can instruct you on how

 

 

to test the Heat/Cool/ system for correct operation. If the

 

 

system operates correctly, replace the thermostat.

 

 

 

Furnace Cycles Too Fast

1. The location of the thermostat and/or

Item 4 in the Configuration Menu is the adjustment that

or Too Slow (narrow or

the size of the Heating System may be

controls the cycle rate. If an acceptable cycle rate is not

wide temperature swing)

influencing the cycle rate.

achieved using the FA (Fast) or SL (Slow) adjustment con-

 

 

tact a local service person for additional suggestions.

 

 

 

Cooling Cycles Too Fast

1. The location of the thermostat and/or

The cycle rate for cooling is fixed and can not be adjusted.

or Too Slow (narrow or

size of the Cooling System may be

Contact a local service person for suggestions.

wide temperature swing)

influencing the cycle rate.

 

 

 

 

Thermostat Setting and

1. Thermostat thermometer setting

The thermometer can be adjusted +/-4 degrees as listed in

Thermometer Disagree

requires adjustment.

item 8 of the Configuration Menu. No other adjustment is

 

 

possible.

 

 

 

Clock Loses or Gains

1. Loss of power to thermostat.

The thermostat will maintain its program in memory even

Time

 

with no power but the clock time will be incorrect when

 

 

power is restored. See No Heat/No Cool/No Fan (common

 

 

problems) above for items to check in the system.

 

 

 

Heat or Cool Starts Early

1. EMR activated.

See Configuration Menu (Item 3).

 

 

 

Thermostat Does Not

1. AM or PM set incorrectly in program.

Check current clock and program settings including the AM

Follow Program

2. AM or PM set incorrectly on the clock.

or PM designations for each time period. If a voltage spike

 

3. Voltage spike or static discharge.

or static discharge occurs use the Reset Operation listed

 

4. See “Heat or Cool Starts Early” above.

above.

 

 

 

Blank Display and/or

1. Voltage Spike or Static Discharge.

If a voltage spike or static discharge occurs use the Reset

Keypad Not Responding

 

Operation listed above.

 

 

 

9

Page 9
Image 9
White Rodgers 1F82-0261 specifications Troubleshooting, Reset Operation

1F82-0261 specifications

The White Rodgers 1F82-0261 is a highly versatile and efficient programmable thermostat designed for residential applications. This device caters to homeowners who seek to optimize their heating and cooling systems while maintaining comfort and energy savings. Aimed at providing user-friendly functionality with advanced technology, it embodies a perfect blend of comfort and control.

One of the standout features of the 1F82-0261 is its easy-to-read, backlit display. This clear interface ensures that users can effortlessly read the current temperature at a glance, even in low-light conditions. The thermostat offers four programmable periods per day, allowing for extensive customization of heating and cooling schedules. Users can set different temperatures for mornings, days, evenings, and nights, accommodating varied household lifestyles and ensuring energy efficiency.

The device operates on a straightforward menu-driven programming system which simplifies the setup process. Users can easily navigate through options to create personalized schedules, making it simpler than ever to tailor climate control to individual preferences. Furthermore, the memory backup system protects user settings in case of a power outage, ensuring that your comfort settings remain intact.

Another notable characteristic is the compatibility of the 1F82-0261 with various heating and cooling systems. This thermostat works well with single-stage heating, heating only, cooling only systems as well as multi-stage systems, making it a flexible choice for diverse home setups.

The energy-saving features integrated into the 1F82-0261 help homeowners to manage their utility costs effectively. A key feature is the Energy Star designation, which indicates that the thermostat meets stringent energy efficiency guidelines. Additionally, the thermostat’s built-in reminders for filter changes contribute to maintaining system efficiency while prolonging the life of HVAC equipment.

In terms of installation, the White Rodgers 1F82-0261 is designed for ease of use. It includes a universal mounting plate for compatibility with various existing systems, and the installation process is straightforward, appealing to both novice DIYers and professionals.

In summary, the White Rodgers 1F82-0261 embodies modern technology with its user-friendly interface, energy-saving capabilities, and broad compatibility. It is a sought-after solution for homeowners looking to enhance comfort while making efficient use of their heating and cooling systems. This thermostat not only promises ease of use but also aims to deliver significant savings on energy bills, making it an intelligent choice for any household.