CONFIGURATION MENU

Press the SYSTEM button until OFF is displayed, then press the and simultaneously

INSTALLER/CONFIGURATION MENU

 

Press

Displayed

Press or

 

Step

Button(s)

(Factory Default)

to select

Comments

1

System

MS 2

SS1, HP2, HP1

Selects Single Stage, Multi-Stage, or Heat Pump

 

 

 

 

 

 

(Single Stage or 2-stage) System Configuration

 

 

 

 

 

 

 

2

System

PRG 4

PRG 0, PRG 2

Selects Programmable Periods

 

 

 

 

 

 

 

3

System

4:00 HOLD

0:15 to 8:00

Selects Temporary Program Override Time

 

 

 

 

 

(increments of 15 minutes)

 

 

 

 

 

 

 

 

4

System

EMR

OFF

Selects Energy Management Recovery OFF or ON

 

 

(ON)

 

 

 

 

 

 

 

 

 

5

System

FA

SL

Selects Fast or Slow Cycle Selection

 

 

 

 

 

 

 

6

System

CL

CL

Selects Compressor Lockout CL OFF or ON

 

 

(OFF)

(ON)

 

 

 

 

 

 

 

 

7

System

CDL

CDL

Selects Backlight Display

 

 

(ON)

(OFF)

 

 

 

 

 

 

 

 

8

System

FA

FA

Selects Fast Second Stage ON or OFF

 

 

(ON)

(OFF)

(Not available if SS1 is selected above)

 

 

 

 

 

 

 

9

System

0 FLTR

50-1950(increments of 50)

Selects filter replacement run time

 

 

 

 

 

 

 

10

System

0°F

4 LO to 4 HI

Selects Temperature Display Adjustment 4 LO to 4 HI

 

 

(Room Temperature)

 

 

 

 

 

 

 

 

 

11

System

°F

°C

Selects temperature display or °C selection

12

System

AU On

OFF

Selects AUTO Mode ON or OFF

 

 

 

 

 

 

 

13

System

LR

LR 62 to LR89

Selects Limited HEAT range

 

 

(90)

 

 

14

System

LR

LR 46 to LR 82

Selects Limited COOL range

 

 

(45)

 

 

15

System

 

 

 

(ON)

Selects Keypad Lockout

 

 

 

 

 

(OFF)

 

 

 

 

 

 

 

16

System

000

001 to 999

Selects Keypad lockout combination number

 

 

 

 

 

 

Press System to set code

17

Run

 

 

 

 

Returns to the OFF position

 

 

 

 

 

 

 

tem key selection will skip EMR (item 4) and temporary program override (item 3).

3)Select Temporary Program Override Time – The thermo- stat can hold any temperature you set it to for the amount of time you select on this option. Your choices are 0:15 to 8:00 hours in 15 minute increments.

Example:

a.You have selected 3:00 hours for the Temporary Pro- gram Override time period.

b.With the thermostat set to Heat or Cool, press or to set the temperature to your preference. The thermostat will maintain this temperature setting for 3 hours with “HOLD” blinking to remind you it is in Temporary Hold. After 3 hours, the thermostat will

go back to the program temperature and “HOLD” will no longer blink or display.

4)Select Energy Management Recovery OFF or ON – Energy Management Recovery (EMR) causes the thermo- stat to start heating or cooling early to make the building temperature reach the program setpoint at the time you specify. Heating will start 5 minutes early for every 1° of temperature required to reach setpoint. Cooling allows more time per degree because it takes longer to reach temperature.

Example: You select EMR and have your heating program- med to 65° at night and 70° at 7 AM. If the building temp- erature is 65° the difference between 65° and 70° is 5°. Allowing 5 minutes per degree the thermostat setpoint will change to 70° at 6:35 AM.

6

Page 6
Image 6
White Rodgers 1F85-275 installation instructions INSTALLER/CONFIGURATION Menu

1F85-275 specifications

The White Rodgers 1F85-275 is a versatile and innovative thermostat designed to provide homeowners with precise control over their heating and cooling systems. Its user-friendly interface and advanced technologies make it a popular choice for those looking to optimize their indoor climate efficiently.

One of the standout features of the 1F85-275 is its ability to control both heating and cooling systems, making it an all-in-one solution for year-round comfort. This thermostat is compatible with a wide range of HVAC systems, including gas, oil, electric, and heat pump systems. This compatibility ensures that homeowners can easily integrate the 1F85-275 into their existing setup without the need for extensive modifications.

A key characteristic of the 1F85-275 is its large, easy-to-read display. The digital interface allows users to view and adjust the temperature settings effortlessly. Additionally, the backlit display makes it convenient to read in low-light conditions, ensuring that adjustments can be made at any time of the day.

The 1F85-275 incorporates advanced scheduling capabilities, allowing homeowners to set specific temperature programs for different times of the day and days of the week. This feature promotes energy efficiency by enabling users to reduce heating or cooling when they are not at home or during sleeping hours. The intuitive programming options make it easy to customize settings according to individual preferences and lifestyles.

Another notable technology feature is the thermostat’s adaptive recovery capability. This technology automatically learns how long it takes for the home to reach the desired temperature, allowing it to start heating or cooling ahead of time. This ensures the home reaches the set temperature at the designated time, providing maximum comfort when needed most.

Moreover, the 1F85-275 includes a filter change indicator, reminding users when it’s time to replace or clean air filters. This not only enhances the efficiency of the HVAC system but also contributes to better indoor air quality.

The thermostat is also designed with energy-saving features in mind. Its precise temperature control and scheduling options can lead to significant savings on energy bills over time. With easy installation and clear instructions, users can have their 1F85-275 up and running in no time, making it an excellent choice for both tech-savvy users and those new to smart home technology.

In summary, the White Rodgers 1F85-275 combines user-friendly features, advanced technology, and energy-efficient operation, making it a compelling choice for homeowners seeking to enhance their indoor comfort while keeping energy costs in check.