INSTALLER/CONFIGURATION MENU
Thermostat must be in Heat, Cool or Auto. Press and hold the Menu button for at least 5 seconds. The display will show item
#1 in the table below. Press Menu to advance to the next menu item. Press or to change a menu item options.
INSTALLER/CONFIGURATION MENU
Menu | HP | SS | Press | Displayed | Press | or | Comments |
Ref. |
|
| Button | (Factory Default) | to select from listed |
| |
|
|
|
|
| options |
| |
|
|
|
|
|
|
| |
1 | 1 | 1 | MENU | (MS 2) | HP 1, HP 2, SS 1 | Selects | |
|
|
|
|
|
|
| Heat Pump 1 (HP 1, 1 compressor), |
|
|
|
|
|
|
| Heat Pump 2 (HP 2, 2 compressor or 2 |
|
|
|
|
|
|
| speed compressor), or Single Stage (SS 1) |
|
|
|
|
|
|
|
|
2 | 2 | 2 | MENU | (GAS) for SS or MS |
| ELE | GAS setting: furnace controls the blower |
|
|
|
| (ELE) for HP |
|
| ELE setting: thermostat controls the blower |
|
|
|
|
|
|
| |
3 | 3 | 3 | MENU | CS (3) | 0, 1, 2, 4, 5, 6 | Selects Cool Savings | |
|
|
|
|
|
|
| Value 1 (low) to 6 (high), |
|
|
|
|
|
|
| Value 0 disables feature |
|
|
|
|
|
|
|
|
4 | 4 | 4 | MENU | E (On) |
| OFF | Selects Energy Management Recovery (EMR) |
|
|
|
|
|
|
| On or OFF. |
|
|
|
|
|
|
|
|
5 | – | 5 | MENU | CR Heat (ME) |
| SL, FA | Selects Adjustable Anticipation, cycle rate, Heat |
|
|
|
|
|
|
| (This item only appears when MS 2 or SS 1 is |
|
|
|
|
|
|
| selected above) |
|
|
|
|
|
|
|
|
6 | 5 | – | MENU | CR Heat Pump |
| SL, FA | Selects Adjustable Compressor Anticipation |
|
|
|
| (ME) |
|
| (Heat Pump) This item only appears when |
|
|
|
|
|
|
| HP 1, HP 2 is selected above |
|
|
|
|
|
|
|
|
7 | 6 | 6 | MENU | CR Cool (ME) |
| SL, FA | Selects Adjustable Anticipation, cycle rate, cool |
|
|
|
| or |
|
| (when MS 2 or SS 1 is selected above.) or |
|
|
|
| CR AU (FA) |
| SL | Selects the cycle rate for Auxiliary stage (when |
|
|
|
|
|
|
| HP 1 or HP 2 is selected above) |
|
|
|
|
|
|
|
|
8 | 7 | 7 | MENU | CL (OFF) |
| CL On | Compressor Lockout Time |
|
|
|
|
|
|
| |
9 | 8 | 8 | MENU | Em Heat, Auto | Heat Cool Off, | System Mode Confi guration | |
|
|
|
| Cool Off | Heat Off with Fan icon, | with Automatic Changeover capability | |
|
|
|
| or | Heat Off without Fan icon |
| |
|
|
|
| Heat, Auto,Cool Off | Cool Off, Auto Off |
| |
|
|
|
|
|
|
| |
10 | 9 | 9 | MENU | dL (On) | dL OFF | Selects Display Light On or OFF | |
|
|
|
|
|
|
| |
11 | 10 | 10 | MENU | 0 | 1 HI, 2 HI, 3HI, 4 HI, | Adjustable Ambient Temperature Display | |
|
|
|
| (current temperature) | 1 LO, 2 LO, 3 LO, 4 LO |
| |
|
|
|
|
|
|
|
|
12 | 11 | 11 | MENU | °F |
| °C | Selects Fahrenheit/Celsius Temperature Display |
|
|
|
|
|
|
|
|
13 | 12 | 12 | MENU | (On) b |
| OFF | May select Beeper OFF to stop audible |
|
|
|
|
|
|
| key feedback |
|
|
|
|
|
|
|
|
14 | 13 | 13 | MENU | P (7) |
| 3, 0 | Defaults |
|
|
|
|
|
|
| programmable (0) or 5/1/1 programming (P3) |
|
|
|
|
|
|
| is available on most models. |
|
|
|
|
|
|
|
|
15 | 14 | 14 | MENU | PS (4) |
| 2 | Selects Program periods per day: |
|
|
|
|
|
|
| 4 = Morn, Day, Eve, Night |
|
|
|
|
|
|
| 2 = Day, Night |
|
|
|
|
|
|
|
|
16 | 15 | 15 | MENU | Heat AS (On) |
| OFF | Automatic Schedule for heat mode |
|
|
|
|
|
|
|
|
17 | 16 | 16 | MENU | Cool AS (On) |
| OFF | Automatic Schedule for cool mode |
|
|
|
|
|
|
|
|
18 | 17 | – | MENU | Heat FA (On) |
| OFF | Fast Heat option may be disabled by |
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 confi g. |
|
|
|
|
|
|
|
|
19 | 18 | – | MENU | Cool FA (On) |
| OFF | Fast Cool option may be disabled by |
|
|
|
|
|
|
| selecting OFF. NA to SS or HP1 confi g. |
|
|
|
|
|
|
|
|
20 | 19 | 17 | MENU | Remote (OFF) |
| On | Selects Remote Sensor On/OFF |
|
|
|
|
|
|
| |
|
|
| MENU | Remote | Outdoor | Selects Remote Sensor to outdoor | |
|
|
|
| (In) |
|
| NA is Remote Sensor OFF |
|
|
|
|
|
|
|
|
|
|
| MENU | Indoor Loc |
| OFF | Selects Local Sensor (in thermostat) to OFF. |
|
|
|
| (On) |
|
| N/A if Remote is selected to Outdoor |
|
|
|
|
|
|
|
|