WIRING DIAGRAMS

Figure 1 – Heat Pump Systems

Jumper

 

L

O/B

Y

Y2

W/E

 

W2

G

RH

RC

C

A1

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Heat Pump 1

 

 

O

 

 

 

 

 

Heat Mode

 

Heat Mode

Blower/

 

 

 

 

 

 

 

 

(HP1)

 

 

Energized in

 

 

 

 

 

2nd Stage

 

3rd Stage.

Circulator

 

 

 

 

 

 

 

 

Diagnostic

 

 

No

 

 

Emergency

 

 

 

 

 

 

 

 

 

Cool Mode

Heat and

 

 

 

 

Fan Energized

24 Volt

24 Volt

Optional*

 

 

 

Indicator

 

 

Output

Emergency

 

Mode 2nd

on Call for

24 Volt

 

 

 

or System

B

Cool Mode

 

Stage

(Hot)

(Hot)

 

 

 

 

 

 

 

Heat or Cool.

(Com-

 

 

 

Malfunction

1st Stage

 

 

 

Mode

 

 

 

Heat

Cool

 

 

Heat Pump 2

Energized in

2nd

 

Heat Mode

Set Elect/Gas

mon)

 

 

Switch

(Compressor)

1st Stage

 

 

 

 

 

 

 

(HP2)

 

 

Heat, Off,

 

 

Stage

 

 

 

 

4th Stage.

Option for

 

 

 

 

 

 

 

 

 

 

 

Emergency

 

 

(Com-

Heat mode

 

Emergency

Emergency

 

 

 

 

 

 

 

 

 

 

 

Mode

 

 

pressor)

3rd Stage

 

Mode 2nd

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stage

 

 

 

 

 

 

 

 

 

 

Heat Pump Connections

If you do not have a heat pump system, refer to figures 2 & 3.

Refer to equipment manufacturers' instructions for specific system wiring information.

You can configure the thermostat for use with the following heat pump systems.

HEAT PUMP TYPE 1 (HP 1). Single stage

compressor system; gas or electric backup.

Comfort Alert II Module

 

or Similar System

NEUTRAL

Diagnostic Module

24VAC

See Module Instructions

HOT

for details

 

* Common connection required for diagnostic or malfunction indication.

CLASS II

TRANSFORMER

HEAT PUMP TYPE 2 (HP 2). Multi-stage 120VAC compressor or two compressor system with

gas or electric backup.

After wiring, see INSTALLER CONFIGURA- TION section for proper thermostat configura- tion.

Figure 2 – Single Stage or Multi-Stage System (No Heat Pump)

with Single Transformer

Jumper

 

 

L

O/B

Y

Y2

W/E

W2

G

RH

RC

C

A1

System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Single

Diagnostic

O

 

 

 

 

 

 

 

 

Blower/

 

 

 

 

 

 

 

 

Energized Constantly

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stage 1

 

 

 

 

 

 

No Output

Circulator

 

 

 

 

 

 

 

 

Indicator

in

 

 

No

 

 

 

 

 

 

 

 

 

 

(SS1)

 

 

Heat

 

 

Fan Energized

24 Volt

24 Volt

Optional*

 

 

Input

Cool Mode

 

 

 

 

 

 

 

Cool Mode

Output

Mode

 

 

on Call for

(Hot)

(Hot)

24 Volt

 

 

 

or

 

 

 

 

 

 

 

System

B

1st Stage

 

 

1st Stage

 

 

Cool (and

Heat

Cool

(Com-

 

 

Multi-

Malfunction

 

 

Cool

 

 

Heat Mode

Heat if

 

 

 

 

mon)

 

 

Stage 2

Switch

Energized Constantly

 

 

Mode

 

 

2nd Stage

configured

 

 

 

 

 

 

 

 

in Heat, Off,

 

 

 

 

for Electric

 

 

 

 

 

 

 

 

(MS2)

Input

 

 

2nd

 

 

 

 

 

 

 

 

 

 

 

 

 

Emergency

 

 

Stage

 

 

 

 

Heat)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Mode

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Comfort Alert II Module

NEUTRAL

or Similar System

Diagnostic Module

24VAC

See Module Instructions

HOT

for details

 

Single Stage and Multi-Stage Con- nections

Refer to equipment manufacturers' instructions for specific system wiring information.

This thermostat is designed to operate a single-transformer or two-transformer system.

You can configure the thermostat for use with the following fossil fuel systems:

SINGLE STAGE (SS 1) gas, oil or electric.

MULTI-STAGE (MS 2) gas, oil or electric. After wiring, see INSTALLER CONFIGURA- TION section for proper thermostat configura-

120VAC tion.

CLASS II

TRANSFORMER

* Common connection required for diagnostic or malfunction indication.

Figure 3 – Single Stage or Multi-Stage System (No Heat Pump)

with Two Transformers

 

 

 

 

 

 

 

 

 

Jumper

Remove Jumper Wire

 

 

 

 

 

 

 

 

 

between RH & RC

 

L

O/B

Y

Y2

W/E

W2

G

RH

RC

C

System

 

 

 

 

 

 

 

 

 

 

 

Single

 

O

B

 

 

 

 

Blower/

 

 

 

Stage 1

 

 

 

 

No Output

Circulator

 

 

 

(SS1)

Diagnostic

Energized

Energized

 

No

Heat

 

Fan Energized

24 Volt 24 Volt

Optional

 

Indicator

Constantly

Constantly

Cool Mode

Output

Mode

 

on Call for

(Hot)

(Hot)

24 Volt

Multi-

(Optional)

in

in Heat, Off, 1st Stage

Cool

1st Stage

Heat Mode

Cool (and

Heat

Cool

(Com-

 

Cool Mode

Emergency

 

 

Heat if

 

 

mon)

Stage 2

 

 

Mode

 

Mode

 

2nd Stage

configured

 

 

 

(MS2)

 

 

 

 

2nd

 

 

for Electric

 

 

 

 

 

 

 

 

Stage

 

 

Heat)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NEUTRAL

NEUTRAL

 

 

 

 

 

 

 

 

 

24VAC

 

 

 

 

 

 

 

 

 

HOT

120VAC

24VAC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

HOT

 

 

 

 

 

 

 

 

 

CLASS II

HEATING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

CLASS II

 

 

 

 

 

 

 

 

 

 

 

TRANSFORMER

 

 

 

 

 

 

 

 

 

 

 

NOTE: If continuous backlight or hard- wired power input are desired but do not function in both HEAT and COOL modes, cut the heating transformer 24V wires and tape off. Connect the neutral circuit disconnected from the heating trans- former to the neutral circuit of the cooling transformer. Disconnect the wire to the RH terminal and install a jumper between RH and RC. Depending on the system requirements, replace the cooling trans- former with a 75VA class II transformer if

needed.

120VAC

COOLING

Figure 4 – 3-Wire (SPDT) Heat Only Zone Valve Wiring

 

 

 

 

Jumper

 

6

Y

W

G

RH RC

C

System

Single Stage 3-wire Zone Valve application

Closes

Valve

(6)

Opens

Valve

(4)

Blower/Circulator

Fan Energized

24 Volt

24 Volt

Constant

24 Volt

(Hot)

(Hot)

(Com-

Heat

Cool

mon)

(5)

 

 

NEUTRAL

24VAC

HOT

120VAC

CLASS II

TRANSFORMER

3

Page 3
Image 3
White Rodgers 1F95-0680 specifications Wiring Diagrams, Heat Pump Systems