White Rodgers 1F95-1271 Installation, Wiring Connections, Remove Old Thermostat, Battery Location

Models: 1F95-1271

1 8
Download 8 pages 3.21 Kb
Page 2
Image 2
INSTALLATION

INSTALLATION

!WARNING

Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.

Remove Old Thermostat

A standard heat/cool thermostat consists of three basic parts:

1.The cover, which may be either a snap-on or hinge type.

2.The base, which is removed by loosening all captive screws.

3.The switching subbase, which is removed by unscrewing the mounting screws that hold it on the wall or adapter plate. Before removing wires from old thermostat, label each wire with the terminal designation from which it was attached. Disconnect the wires from the old thermostat one at a time. Do not let wires fall back into the wall.

Installing New Thermostat

1.Pull the thermostat body off the thermostat base. Forcing or prying on the thermostat will cause damage to the unit.

2.Place base over hole in wall and mark mounting hole locations on wall using base as a template.

3.Move base out of the way. Drill mounting holes. If you are using existing mounting holes and the holes drilled are too large and do not allow you to tighten base snug- ly, use plastic screw anchors to secure the base.

4.Fasten base snugly to wall using mounting holes shown in Figure 1 and two mounting screws. Leveling is for appearance only and will not affect thermostat operation.

5.Connect wires to terminal block on base using appropriate wiring schematic (see diagram sheet 37-6740A).

6.Push excess wire into wall and plug hole with a fire re- sistant material (such as fiberglass insulation) to prevent drafts from affecting thermostat operation.

7.Carefully line the thermostat up with the base and snap into place.

Battery Location

2 "AA" alkaline batteries are included in the thermostat at the factory with a battery tag to prevent power drainage. Remove the battery tag to engage the batteries.

To replace batteries, set system to OFF, remove thermostat from wall and install the batteries in the rear along the top of the thermostat (see Figure 1).

Figure 1 – Thermostat base and rear view of thermostat

Mounting

W/E

 

Mounting

Hole

 

 

 

W2

 

 

Hole

 

 

 

Y2

 

 

 

 

 

 

 

 

 

 

 

Place Level

 

 

 

Place Level

across

 

 

 

 

 

 

across

 

 

 

 

 

Mounting Tabs

 

 

Mounting Tabs

(for appearance only)

 

(for appearance only)

2 "AA" Batteries

WIRING CONNECTIONS

Refer to equipment manufacturers' instructions for specific

For wiring diagrams, see 37-6740A.

system wiring information. After wiring, see CONFIGURA-

Wiring diagrams shown are for typical systems and describe

TION section for proper thermostat configuration.

the thermostat terminal functions.

TERMINAL DESIGNATION DESCRIPTIONS

 

 

 

 

Terminal Designation

Description

 

L

Heat pump malfunction indicator for

 

systems with malfunction connection

O

Changeover valve for heat pump energized

 

constantly in cooling

 

B

Changeover valve for heat pump energized

 

constantly in heating

 

Y

Compressor Relay

 

Y2

2nd Stage Compressor

 

W/E

Heat Relay/Emergency Heat Relay (Stage 1)

W2

2nd Stage Heat (3rd Stage Heat in HP2)

G

Fan Relay

 

RH

Power for Heating

 

RC

Power for Cooling

 

C

Common wire from secondary side of cooling

 

system transformer or heat only system transformer

 

 

 

2

Page 2
Image 2
White Rodgers 1F95-1271 Installation, Wiring Connections, Remove Old Thermostat, Installing New Thermostat, Description